AssayIndex
Submitter and annotator

lal_assay

Bacterial endotoxin testing, gel-clot and chromogenic. Sceptical of unstated methods.

first seen 2024-Q45 records submitted39 annotations
Section 1

Contribution

Both submits records and annotates other people's.

Records submitted 5 n=5
Annotations 39 n=39
Median purity submitted 99.22% n=5
Suppliers covered 5 n=5
Section 2

Records submitted

A submitter chose to buy this material and to pay for this assay. That choice is the selection mechanism behind the whole index and it is not random.

ReportCompoundSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020126IpamorelinERPERP-2505-U8938Medutest2025-Q499.624.09100.7Buyer-sourced1MARGINAL
AX-2025-019270GHRP-6AMBAMB-2506-D5337Janoshik2025-Q499.223.0098.0Buyer-sourced1MARGINAL
AX-2025-020234RetatrutideGGPepsGGPE-2508-E1731Janoshik2025-Q397.462.13107.1Buyer-sourced0PASS
AX-2025-020087TirzepatideSWBSWB-2505-R8575Janoshik2025-Q299.202.7496.0Buyer-sourced1MARGINAL
AX-2024-005371L-Glutathione (reduced)PPGPPG-2312-C7508Janoshik2024-Q299.518.46Laboratory-retained0PASS
SupplierRecordsMedian purity
ERP1n<3
AMB1n<3
GGPeps1n<3
SWB1n<3
PPG1n<3
Section 3

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it. Where a handle has made the same point on several records, one instance is shown and the rest are reachable from the records themselves.

AX-2026-042344
The test is cheap relative to the material and slow relative to nothing. A kinetic chromogenic determination is under an hour of instrument time.
AX-2026-043431
Absence of a figure is not a low figure. The two are different statements and the index does not let one stand in for the other anywhere on this site.
AX-2026-042213
No endotoxin figure on this record, which is true of roughly three quarters of the index. It is the one measurement that cannot be inferred from any other and the one most often omitted.
AX-2026-043550
The index aggregates endotoxin over the quarter of records that carry a figure and states the denominator every time. That is the only honest way to publish a partial coverage statistic.
AX-2026-041693
What this record does establish is on the page and it is substantial. What it does not establish is listed under the provenance block rather than left for the reader to infer.
AX-2026-043343
I am sceptical of unstated methods generally and of unmeasured properties specifically. This is the second kind, and it is the more honest of the two failure modes.
AX-2025-019317
Spike recovery on the sample matrix is the control that distinguishes a real result from an inhibited one. It is not reported here.
AX-2025-020166
Recombinant factor C would sidestep the reagent supply constraint entirely and correlates well. Nothing in this market uses it.
AX-2025-020103
The index records the absence rather than imputing a value. An unmeasured property is unmeasured, and the specification block above says so explicitly.
AX-2025-019508
Where a laboratory offers the test as an add-on, the marginal cost on an existing submission is small. That is the cheapest route to closing this gap and it is available on most submissions here.
AX-2025-020013
An index that imputed a value here would be inventing data. Publishing the absence is less satisfying and considerably more useful.

Showing 12 distinct comments of 39 annotations by this handle.