AssayIndex

AX-2025-020890

5-Amino-1MQ · 100 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · lot WXT-2505-M2430

FAILIDENTITY CONSISTENT
Report ID
AX-2025-020890
Compound
5-Amino-1MQ
Compound class
Non-peptide adjuncts
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Batch / lot
WXT-2505-M2430
Declared label claim
100mg
Laboratory
Medutest
Assay date
28 Apr 2025
Submitted
07 May 2025
Quarter
2025-Q2
Submitter
r.nwosu
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm98.27% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks1.73% area≤ 2.0PASS
Largest single impurityRP-HPLC — 1-methylquinolinium (des-amino, −15 Da)1.24% area≤ 1.00FAIL
Identity — theoretical monoisotopic masscalculated from molecular formula285.9967DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)285.9962DaNOT TESTED
Mass accuracyobserved vs theoretical-1.6ppm± 10PASS
Total peptide contentby difference from the gravimetric mass balance51.81%w/wNOT TESTED
Target-compound contenttotal peptide content × purity50.91%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen197.36mg100 mg declaredNOT TESTED
Recovered target peptidegross fill × target content100.476mg100 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim100.5%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate2.90%≤ 10.0PASS
Counter-ion (iodide)anion-exchange ion chromatography44.92%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.37%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.692.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient4.56min4.59 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.150.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²50,597≥ 20,000PASS
Resolution to nearest impurityvs free iodide (counter-ion, by IC)0.00no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

05226104521567920905 5-Amino-1MQ4.56 min · 98.27 % 4.29 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 50,597, and skew follows the reported asymmetry factor of 1.15. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 1.24 % impurity against a 98.27 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
15-Amino-1MQ — main peak4.564,776,22798.27
21-methylquinolinium (des-amino, −15 Da)4.2960,2681.24-15.011
38-amino regioisomer4.7413,6090.280.000
4free iodide (counter-ion, by IC)4.565,8320.120.000
55-nitro-1MQ (unreduced precursor, +30 Da)5.134,3740.09+29.974
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 285.9967 Da, computed from C10H11N2+ · I−. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250275300325350375 [M+1H]1+287.00 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 285.9962 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
1+287.0040287.0035-0.0005100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer2.90
Counter-ion (iodide)ion chromatography44.92
Residual solvent + inorganic residueestimated0.37
Total peptide contentby difference51.81
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.0998.27divergence +0.38 pp vs batch median
Total impurities (% area)0.911.73
Largest single impurity (% area)0.511.24
Water (%)not stated2.90
Counter-ion (%)7.944.92
Peptide content (%w/w)88.051.81
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 11 d) → laboratory (courier, dry ice, 10 d) → assay.
Assay date
28 Apr 2025
Submitted to the index
07 May 2025
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

plate_count
Where the plate count is low the resolution figure is low for a reason that has nothing to do with the impurity profile. Read the two together or read neither.
label_claim
Closure is a property of the index's arithmetic, not evidence about the material. What it establishes is that the four numbers on this record are mutually consistent.
Section 7

Related records

Same batch — lot WXT-2505-M2430 n=9

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020883WXT-2505-M2430Janoshik2025-Q298.712.6690.2Buyer-sourced0FAIL
AX-2025-020884WXT-2505-M2430Medutest2025-Q298.742.93102.5Buyer-sourced0FAIL
AX-2025-020885WXT-2505-M2430Medutest2025-Q299.082.4689.1Supplier-supplied1FAIL
AX-2025-020886WXT-2505-M2430Nordanalyt2025-Q299.342.7798.0Supplier-supplied0FAIL
AX-2025-020887WXT-2505-M2430Janoshik2025-Q298.192.78Buyer-sourced0FAIL
AX-2025-020888WXT-2505-M2430Janoshik2025-Q298.512.7589.4Buyer-sourced1FAIL
AX-2025-020889WXT-2505-M2430VendorInvestigate2025-Q297.982.57Buyer-sourced0FAIL
AX-2025-020891WXT-2505-M2430VendorInvestigate2025-Q298.803.32104.8Buyer-sourced0FAIL
Other recent 5-Amino-1MQ records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043050KPKP-2511-W5347Janoshik2026-Q299.354.16105.5Buyer-sourced0FAIL
AX-2026-043044KPKP-2511-W5347PeptideMeter2026-Q299.614.1590.9Buyer-sourced0FAIL
AX-2026-043052KPKP-2511-W5347Medutest2026-Q299.454.23105.5Buyer-sourced1FAIL
AX-2026-043045KPKP-2511-W5347Janoshik2026-Q299.474.08Buyer-sourced0FAIL
AX-2026-043043KPKP-2511-W5347Janoshik2026-Q299.584.16101.1Buyer-sourced0FAIL
AX-2026-042869GGPepsGGPE-2512-M2434Kestrel2026-Q299.554.65103.9Buyer-sourced0FAIL
AX-2026-042868GGPepsGGPE-2512-M2434PeptideMeter2026-Q299.324.3988.5Buyer-sourced1FAIL
AX-2026-043047KPKP-2511-W5347Janoshik2026-Q299.684.17104.0Supplier-supplied0FAIL
Other recent WXT records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043376SemaglutideWXT-2604-C3248Janoshik2026-Q397.084.22Buyer-sourced1MARGINAL
AX-2026-043429L-Glutathione (reduced)WXT-2605-B3833Nordanalyt2026-Q398.486.5896.9Supplier-supplied1FAIL
AX-2026-043347LeuprolideWXT-2604-K2596PeptideMeter2026-Q399.165.9993.6Buyer-sourced0PASS
AX-2026-043353LeuprolideWXT-2604-K2596Janoshik2026-Q399.194.9095.3Laboratory-retained0PASS
AX-2026-043345LeuprolideWXT-2604-K2596Janoshik2026-Q398.935.28Buyer-sourced0PASS
AX-2026-043424L-Glutathione (reduced)WXT-2605-B3833PeptideMeter2026-Q398.376.86Buyer-sourced0FAIL
AX-2026-043374SemaglutideWXT-2604-C3248Janoshik2026-Q397.003.56Buyer-sourced1MARGINAL
AX-2026-043377SemaglutideWXT-2604-C3248PeptideMeter2026-Q397.204.08Buyer-sourced1MARGINAL