AssayIndex

AX-2026-042963

Adipotide · 5 mg declared · Xi'an Mokemei Biotechnology Co., Ltd. · lot MKM-2511-F3656

MARGINALVERIFIED
Report ID
AX-2026-042963
Compound
Adipotide
Compound class
Metabolic and mitochondrial peptides
Supplier
MKM — Xi'an Mokemei Biotechnology Co., Ltd.
Batch / lot
MKM-2511-F3656
Declared label claim
5mg
Laboratory
VendorInvestigate
Assay date
22 Feb 2026
Submitted
25 Feb 2026
Quarter
2026-Q1
Submitter
sa.achebe
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the metabolic and mitochondrial peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 32 min gradient, 214 nm98.49% area≥ 96.0PASS
Total impuritiesRP-HPLC, sum of reported peaks1.51% area≤ 4.0PASS
Largest single impurityRP-HPLC — truncated KLAKLAK repeat (−781 Da)0.57% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula4095.6238DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)4095.6238DaNOT TESTED
Mass accuracyobserved vs theoretical0.0ppm± 15PASS
Total peptide contentby difference from the gravimetric mass balance86.15%w/wNOT TESTED
Target-compound contenttotal peptide content × purity84.85%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen5.92mg5 mg declaredNOT TESTED
Recovered target peptidegross fill × target content5.023mg5 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim100.5%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate5.69%≤ 9.0PASS
Counter-ion (TFA)anion-exchange ion chromatography7.61%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.55%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration3.882.5 – 8.0PASS
Retention time (observed)RP-HPLC, 32 min gradient14.25min13.52 ± 0.35 (normalised)FAIL
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.180.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²67,976≥ 20,000PASS
Resolution to nearest impurityvs disulfide-scrambled isomer2.09no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01914382757417655 Adipotide14.25 min · 98.49 % 12.5215.12 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 32 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 67,976, and skew follows the reported asymmetry factor of 1.18. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.57 % impurity against a 98.49 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Adipotide — main peak14.254,786,91998.49
2truncated KLAKLAK repeat (−781 Da)12.5227,7040.57-781.512
3trifluoroacetyl adduct (+96 Da)15.1222,8430.47+95.982
4disulfide-scrambled isomer14.7212,1510.250.000
5open-chain (reduced disulfide, +2 Da)13.1310,6930.22+2.016
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 4095.6238 Da, computed from C190H332N60O43. All ppm figures on this site are against monoisotopic values — see why that matters.

02550751005008001100140017002000 [M+4H]4+1024.91[M+5H]5+820.13[M+3H]3+1366.22 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 4095.6238 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
6+683.6112683.6112-0.00008.8
5+820.1320820.1320-0.000051.3
4+1024.91321024.9132-0.0000100.0
3+1366.21521366.2152-0.000049.8
2+2048.81922048.81920.00007.7
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer5.69
Counter-ion (TFA)ion chromatography7.61
Residual solvent + inorganic residueestimated0.55
Total peptide contentby difference86.15
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.3098.49divergence -0.54 pp vs batch median
Total impurities (% area)1.701.51
Largest single impurity (% area)not stated0.57
Water (%)4.05.69
Counter-ion (%)not stated7.61
Peptide content (%w/w)not stated86.15
Endotoxin (EU/mg)0.22not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 13 d) → laboratory (courier, dry ice, 8 d) → assay.
Assay date
22 Feb 2026
Submitted to the index
25 Feb 2026
Laboratory
VendorInvestigate, Riga, Latvia
Method basis
32 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

chain_custody
The index cannot verify that the vial assayed is representative of the lot it came from, and says so on every record. Provenance narrows that gap; it does not close it.
ms_confirm
Retention alone never establishes identity. Retention plus mass does, and where the two disagree it is nearly always retention that is wrong for a documented reason.
lambda_214
Detector cell volume and connecting tubing add extrinsic delay. On a fast method with a small column that delay is a real fraction of the retention window.
Section 7

Related records

Same batch — lot MKM-2511-F3656 n=9

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042961MKM-2511-F3656Medutest2026-Q198.975.40Buyer-sourced1FAIL
AX-2026-042962MKM-2511-F3656PeptideMeter2026-Q198.695.07Buyer-sourced0PASS
AX-2026-042964MKM-2511-F3656Janoshik2026-Q198.845.4488.6Buyer-sourced1MARGINAL
AX-2026-042965MKM-2511-F3656Janoshik2026-Q198.734.85100.4Buyer-sourced0PASS
AX-2026-042966MKM-2511-F3656Medutest2026-Q199.095.26Buyer-sourced0PASS
AX-2026-042967MKM-2511-F3656Kestrel2026-Q199.394.93Buyer-sourced0PASS
AX-2026-042968MKM-2511-F3656VendorInvestigate2026-Q198.835.5299.4Buyer-sourced0PASS
AX-2026-042969MKM-2511-F3656Medutest2026-Q198.915.2688.6Supplier-supplied2MARGINAL
Other recent Adipotide records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043019MKMMKM-2606-K5012Janoshik2026-Q397.615.77105.1Buyer-sourced0PASS
AX-2026-043020MKMMKM-2606-K5012Medutest2026-Q397.735.74Buyer-sourced0PASS
AX-2026-043022MKMMKM-2606-K5012Kestrel2026-Q397.696.33106.9Buyer-sourced0PASS
AX-2026-043023MKMMKM-2606-K5012Medutest2026-Q397.485.56103.7Supplier-supplied0PASS
AX-2026-043024MKMMKM-2606-K5012Kestrel2026-Q398.615.07Buyer-sourced0PASS
AX-2026-043021MKMMKM-2606-K5012VendorInvestigate2026-Q397.745.8396.9Buyer-sourced0PASS
AX-2026-043567SIGSIG-2603-6617Janoshik2026-Q298.543.0896.6Buyer-sourced0PASS
AX-2026-043566SIGSIG-2603-6617PeptideMeter2026-Q298.262.86103.1Buyer-sourced0PASS
Other recent MKM records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042942CJC-1295 (no DAC)MKM-2603-V3346Janoshik2026-Q399.523.43Supplier-supplied0PASS
AX-2026-043019AdipotideMKM-2606-K5012Janoshik2026-Q397.615.77105.1Buyer-sourced0PASS
AX-2026-042939CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.443.39Buyer-sourced0PASS
AX-2026-043020AdipotideMKM-2606-K5012Medutest2026-Q397.735.74Buyer-sourced0PASS
AX-2026-043022AdipotideMKM-2606-K5012Kestrel2026-Q397.696.33106.9Buyer-sourced0PASS
AX-2026-043023AdipotideMKM-2606-K5012Medutest2026-Q397.485.56103.7Supplier-supplied0PASS
AX-2026-042945CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.393.54Laboratory-retained0PASS
AX-2026-042938CJC-1295 (no DAC)MKM-2603-V3346Nordanalyt2026-Q399.473.6795.0Buyer-sourced0PASS