L-Glutathione (reduced) by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for L-Glutathione (reduced), with a class minimum gradient of 15 min, the method is a live explanation.

129 recordsmedian 99.33 %spec 98.5 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik6430minHigh99.22+0.0099.22ADEQUATE
Medutest2025minUnit99.35+0.0899.27ADEQUATE
PeptideMeter1928minHigh99.39-0.0599.44ADEQUATE
Nordanalyt1635minHigh99.41+0.0299.39ADEQUATE
Kestrel6 n=615minUnit99.39+0.2499.15ADEQUATE
VendorInvestigate4 n=432minHigh98.62-0.1198.73ADEQUATE
97.297.798.298.799.299.6100.1JanoshikJanoshik: Q1 98.57, median 99.22, Q3 99.64, n=64n=64PeptideMeterPeptideMeter: Q1 98.89, median 99.39, Q3 99.69, n=19n=19MedutestMedutest: Q1 98.69, median 99.35, Q3 99.85, n=20n=20VendorInvestigateVendorInvestigate: Q1 97.84, median 98.62, Q3 99.45, n=4n=4NordanalytNordanalyt: Q1 98.50, median 99.41, Q3 99.76, n=16n=16KestrelKestrel: Q1 98.94, median 99.39, Q3 99.62, n=6n=6 Purity (% area)
Figure. L-Glutathione (reduced) purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.