Gonadorelin by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for Gonadorelin, with a class minimum gradient of 15 min, the method is a live explanation.

33 recordsmedian 99.12 %spec 98.5 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik1530minHigh99.07+0.0099.07ADEQUATE
Medutest6 n=625minUnit98.95+0.0898.87ADEQUATE
PeptideMeter3 n=328minHigh99.34-0.0599.39ADEQUATE
VendorInvestigate3 n=332minHigh99.10-0.1199.21ADEQUATE
Nordanalyt3 n=335minHigh99.60+0.0299.58ADEQUATE
Kestrel3 n=315minUnit99.75+0.2499.51ADEQUATE
98.198.498.899.199.499.7100.1JanoshikJanoshik: Q1 98.80, median 99.07, Q3 99.67, n=15n=15PeptideMeterPeptideMeter: Q1 99.15, median 99.34, Q3 99.64, n=3n=3MedutestMedutest: Q1 98.81, median 98.95, Q3 99.09, n=6n=6VendorInvestigateVendorInvestigate: Q1 98.79, median 99.10, Q3 99.39, n=3n=3NordanalytNordanalyt: Q1 99.55, median 99.60, Q3 99.77, n=3n=3KestrelKestrel: Q1 99.34, median 99.75, Q3 99.84, n=3n=3 Purity (% area)
Figure. Gonadorelin purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.