SLU-PP-332 by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for SLU-PP-332, with a class minimum gradient of 15 min, the method is a live explanation.

22 recordsmedian 98.88 %spec 98.0 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik830minHigh98.81+0.0098.81ADEQUATE
PeptideMeter5 n=528minHigh98.85-0.0598.90ADEQUATE
VendorInvestigate5 n=532minHigh98.97-0.1199.08ADEQUATE
Medutest2 n=225minUnit99.51, 99.20+0.08ADEQUATE
Nordanalyt1 n=135minHigh98.38+0.02ADEQUATE
Kestrel1 n=115minUnit99.04+0.24ADEQUATE
98.098.398.598.899.199.499.6JanoshikJanoshik: Q1 98.78, median 98.81, Q3 98.98, n=8n=8PeptideMeterPeptideMeter: Q1 98.46, median 98.85, Q3 98.90, n=5n=5MedutestMedutest: Q1 99.28, median 99.36, Q3 99.43, n=2n=2VendorInvestigateVendorInvestigate: Q1 98.28, median 98.97, Q3 99.05, n=5n=5 Purity (% area)
Figure. SLU-PP-332 purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.