AssayIndex
Submitter and annotator

sec_monomer

Size-exclusion chromatography for aggregate and oligomer content.

first seen 2025-Q17 records submitted40 annotations
Section 1

Contribution

Both submits records and annotates other people's.

Records submitted 7 n=7
Annotations 40 n=40
Median purity submitted 98.58% n=7
Suppliers covered 6 n=7
Section 2

Records submitted

A submitter chose to buy this material and to pay for this assay. That choice is the selection mechanism behind the whole index and it is not random.

ReportCompoundSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043444BPC-157BCHBCH-2603-G4350Medutest2026-Q398.075.05104.6Buyer-sourced1MARGINAL
AX-2026-041885SemaglutideSinoPepSNP-2511-P4283Janoshik2026-Q297.553.75106.7Buyer-sourced0PASS
AX-2025-018540GHRP-2QYBQYB-2510-D4215Janoshik2025-Q498.874.30103.5Buyer-sourced0FAIL
AX-2025-019201BPC-157SinoPepSNP-2506-U4547Medutest2025-Q398.555.12105.6Buyer-sourced1MARGINAL
AX-2025-020084TirzepatideSWBSWB-2505-R8575Medutest2025-Q298.582.60105.5Buyer-sourced1MARGINAL
AX-2024-004370L-Glutathione (reduced)FGPFGP-2405-E9260Janoshik2024-Q399.565.7293.9Buyer-sourced0PASS
AX-2024-005358MK-677 (Ibutamoren mesylate)SIGSIG-2404-6898Janoshik2024-Q398.933.02104.7Buyer-sourced0FAIL
SupplierRecordsMedian purity
SinoPep2n<3
BCH1n<3
QYB1n<3
SWB1n<3
FGP1n<3
SIG1n<3
Section 3

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it. Where a handle has made the same point on several records, one instance is shown and the rest are reachable from the records themselves.

AX-2026-043424
Aggregate content on a folded peptide is a stability-indicating parameter and reverse phase measures it badly. That is a method limitation rather than a material finding.
AX-2026-042603
Where the close neighbour is an aggregate rather than a related substance, size exclusion separates them trivially and reverse phase never will.
AX-2026-043024
Size exclusion separates monomer from dimer and higher oligomer where reverse phase merges them. On a folded sequence it is the more informative first look.
AX-2026-043268
Reverse phase on a folded peptide partially denatures it on-column, which is why the same lot can give different profiles at different column temperatures. Size exclusion under native conditions does not.
AX-2025-020547
Polydispersity index from size exclusion is the standard descriptor for the polymer and it is absent from every certificate the index holds for this class.
AX-2025-020368
A single size-exclusion injection would give monomer, dimer and higher-order content. It is the highest-value missing measurement on this class of record.

Showing 6 distinct comments of 40 annotations by this handle.