AssayIndex

AX-2024-004591

Melanotan II · 10 mg declared · Tianjin Finder Chemical Co., Ltd. · lot TFC-2401-J9617

PASSIDENTITY CONSISTENT
Report ID
AX-2024-004591
Compound
Melanotan II
Compound class
Melanocortin-receptor peptides
Supplier
TFC — Tianjin Finder Chemical Co., Ltd.
Batch / lot
TFC-2401-J9617
Declared label claim
10mg
Laboratory
PeptideMeter
Assay date
05 Apr 2024
Submitted
18 Apr 2024
Quarter
2024-Q2
Submitter
pt141_one_da
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the melanocortin-receptor peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm99.42% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.58% area≤ 1.5PASS
Largest single impurityRP-HPLC — linear (open-lactam) precursor (+18 Da)0.30% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula1023.5402DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)1023.5339DaNOT TESTED
Mass accuracyobserved vs theoretical-6.2ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate3.55%≤ 8.0PASS
Counter-ion (acetate)anion-exchange ion chromatography3.58%≤ 10.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.49%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureFaint haze, clearing on standingclear, no visible particulatesFAIL
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.912.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient9.13min9.24 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.030.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²86,179≥ 20,000PASS
Resolution to nearest impurityvs [L-Phe7]-diastereomer1.17no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0364672911093714583 Melanotan II9.13 min · 99.42 % 8.44 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 86,179, and skew follows the reported asymmetry factor of 1.03. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.30 % impurity against a 99.42 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Melanotan II — main peak9.134,832,12099.42
2linear (open-lactam) precursor (+18 Da)8.4414,5810.30+18.011
3[L-Phe7]-diastereomer8.988,2630.170.000
4oxidised Trp (+16 Da)8.792,9160.06+15.995
5des-acetyl MT-II (−42 Da)8.682,4300.05-42.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 1023.5402 Da, computed from C50H69N15O9. All ppm figures on this site are against monoisotopic values — see why that matters.

025507510025040055070085010001150 [M+1H]1+1024.54[M+2H]2+512.77 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 1023.5339 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
3+342.1873342.1852-0.00218.9
2+512.7774512.7742-0.003259.4
1+1024.54751024.5412-0.0063100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.8799.42divergence +0.47 pp vs batch median
Total impurities (% area)0.130.58
Largest single impurity (% area)0.050.30
Water (%)3.13.55
Counter-ion (%)8.03.58
Peptide content (%w/w)88.3not determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → third-party forwarder (12 d) → laboratory (courier, cold pack, 4 d) → assay.
Assay date
05 Apr 2024
Submitted to the index
18 Apr 2024
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sig_figs
Two decimal places on 99.42 % implies repeatability better than 0.01 pp, which no laboratory here claims. The number is sound; the printed precision is more than the method carries.
Index data team

Two decimal places are retained because the source reports carry them and truncating would discard information where a laboratory genuinely reports it. The uncertainty budget on /methods/uncertainty-budget/ is the right thing to read alongside any purity figure on this site.

aib_coupling
Hindered couplings are where a synthesis loses purity, and the deletion products they leave are the first thing to look for. On this record they are not there in quantity.
tbu_residual
Residual side-chain protection at +56 Da is the classic silent passenger on a high-purity trace. Nothing at that offset above threshold on this record.
Section 7

Related records

Same batch — lot TFC-2401-J9617 n=2

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004590TFC-2401-J9617PeptideMeter2024-Q299.384.10104.6Buyer-sourced0PASS
Other recent Melanotan II records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042757GGPepsGGPE-2603-P1474Janoshik2026-Q399.546.7892.0Buyer-sourced0PASS
AX-2026-042756GGPepsGGPE-2603-P1474Nordanalyt2026-Q399.177.04Buyer-sourced0PASS
AX-2026-042755GGPepsGGPE-2603-P1474Nordanalyt2026-Q399.256.5890.4Buyer-sourced0PASS
AX-2026-042760GGPepsGGPE-2603-P1474Medutest2026-Q399.437.02Buyer-sourced0PASS
AX-2026-042758GGPepsGGPE-2603-P1474PeptideMeter2026-Q399.236.96Buyer-sourced0PASS
AX-2026-042759GGPepsGGPE-2603-P1474Janoshik2026-Q399.156.71105.1Buyer-sourced0PASS
AX-2026-042168JEEPJEEP-2604-R9103Nordanalyt2026-Q299.405.71Buyer-sourced0PASS
AX-2026-042164JEEPJEEP-2604-R9103Janoshik2026-Q299.545.23Buyer-sourced1MARGINAL
Other recent TFC records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042265Humanin (HNG)TFC-2605-U1300PeptideMeter2026-Q399.526.31Buyer-sourced0PASS
AX-2026-042222SS-31 (Elamipretide)TFC-2607-R9099VendorInvestigate2026-Q399.465.41102.6Buyer-sourced0PASS
AX-2026-042236Humanin (HNG)TFC-2608-S9940Nordanalyt2026-Q398.641.80Buyer-sourced0PASS
AX-2026-042282RetatrutideTFC-2608-J1156Janoshik2026-Q398.544.27Buyer-sourced0PASS
AX-2026-042226SS-31 (Elamipretide)TFC-2607-R9099Janoshik2026-Q399.625.47Buyer-sourced0PASS
AX-2026-042217SemaglutideTFC-2604-X9037PeptideMeter2026-Q398.954.6196.9Buyer-sourced0PASS
AX-2026-042339SermorelinTFC-2605-Y2176Kestrel2026-Q399.934.14Supplier-supplied1FAIL
AX-2026-042214SemaglutideTFC-2604-X9037Kestrel2026-Q399.874.66103.1Laboratory-retained0PASS