AssayIndex

AX-2026-042339

Sermorelin · 2 mg declared · Tianjin Finder Chemical Co., Ltd. · lot TFC-2605-Y2176

FAILIDENTITY CONSISTENT
Report ID
AX-2026-042339
Compound
Sermorelin
Compound class
Growth-hormone axis peptides
Supplier
TFC — Tianjin Finder Chemical Co., Ltd.
Batch / lot
TFC-2605-Y2176
Declared label claim
2mg
Laboratory
Kestrel Bioanalytical
Assay date
25 Sep 2026
Submitted
28 Sep 2026
Quarter
2026-Q3
Submitter
re.sobczak
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 15 min gradient, 214 nm99.93% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 2.0PASS
Largest single impurityRP-HPLC — deamidated Asn8 (+1 Da)0.04% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula3355.7245DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)3355.7826DaNOT TESTED
Mass accuracyobserved vs theoretical+17.3ppm± 15FAIL
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.14%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography4.25%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.78%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.292.5 – 8.0PASS
Retention time (observed)RP-HPLC, 15 min gradient6.58min6.71 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.020.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²54,304≥ 20,000PASS
Resolution to nearest impurityvs deamidated Asn8 (+1 Da)1.30no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0405681121216816224 Sermorelin6.58 min · 99.93 % 6.43 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 048121620 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 15 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 54,304, and skew follows the reported asymmetry factor of 1.02. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.04 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Sermorelin — main peak6.584,856,90899.93
2deamidated Asn8 (+1 Da)6.431,9440.04+0.984
3truncated (1-25)6.061,4580.03-455.248
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 3355.7245 Da, computed from C149H246N44O42. All ppm figures on this site are against monoisotopic values — see why that matters.

02550751005507751000122514501675 [M+3H]3+1119.60[M+2H]2+1678.90[M+4H]4+839.95 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 3355.7826 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
5+672.1522672.16380.01167.9
4+839.9384839.95290.014552.8
3+1119.58211119.60150.0194100.0
2+1678.86951678.89860.029156.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.0199.93divergence -0.14 pp vs batch median
Total impurities (% area)not stated0.07
Largest single impurity (% area)not stated0.04
Water (%)2.84.14
Counter-ion (%)not stated4.25
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)0.27not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 4 d) → assay. Submitter did not handle the vial.
Assay date
25 Sep 2026
Submitted to the index
28 Sep 2026
Laboratory
Kestrel Bioanalytical, Melbourne, Australia
Method basis
15 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

esi_tof
Ion suppression from a co-eluting counter-ion at 4.25 % acetate can shift an apparent mass in a time-of-flight measurement. Desalting the injection before the mass determination removes the possibility.
ppm_error
Worth noting the sign. Calibration drift is usually one-directional across a sequence, so an excursion in the same direction as the laboratory's recent mean is a drift and one against it is something else.
sample_vs_retail
Supplier-supplied provenance. Across the 300 lots in this index where both classes exist for the same lot, supplier-supplied results read a mean 0.42 pp higher (95 % CI 0.38 to 0.46). Read 99.93 % as an optimistic bound rather than a point estimate.
selection_bias
Every headline figure on the corresponding scorecard survives restriction to buyer-sourced records. That sensitivity analysis is published on the scorecard and it is the reason this record can be included at all.
Section 7

Related records

Same batch — lot TFC-2605-Y2176 n=4

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042338TFC-2605-Y2176Janoshik2026-Q398.963.27Supplier-supplied0PASS
AX-2026-042340TFC-2605-Y2176Medutest2026-Q399.343.73106.9Buyer-sourced0PASS
AX-2026-042341TFC-2605-Y2176Janoshik2026-Q398.553.45Buyer-sourced0PASS
Other recent Sermorelin records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043389WXTWXT-2608-P3387Medutest2026-Q398.973.4499.6Supplier-supplied0PASS
AX-2026-042338TFCTFC-2605-Y2176Janoshik2026-Q398.963.27Supplier-supplied0PASS
AX-2026-042341TFCTFC-2605-Y2176Janoshik2026-Q398.553.45Buyer-sourced0PASS
AX-2026-042340TFCTFC-2605-Y2176Medutest2026-Q399.343.73106.9Buyer-sourced0PASS
AX-2026-041954AMBAMB-2512-V5420Medutest2026-Q299.073.72Buyer-sourced0PASS
AX-2026-041958AMBAMB-2512-V5420Janoshik2026-Q299.144.48Buyer-sourced1FAIL
AX-2026-041955AMBAMB-2512-V5420Janoshik2026-Q299.103.17Buyer-sourced0PASS
AX-2026-041957AMBAMB-2512-V5420VendorInvestigate2026-Q299.114.02Buyer-sourced0PASS
Other recent TFC records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042265Humanin (HNG)TFC-2605-U1300PeptideMeter2026-Q399.526.31Buyer-sourced0PASS
AX-2026-042222SS-31 (Elamipretide)TFC-2607-R9099VendorInvestigate2026-Q399.465.41102.6Buyer-sourced0PASS
AX-2026-042236Humanin (HNG)TFC-2608-S9940Nordanalyt2026-Q398.641.80Buyer-sourced0PASS
AX-2026-042282RetatrutideTFC-2608-J1156Janoshik2026-Q398.544.27Buyer-sourced0PASS
AX-2026-042226SS-31 (Elamipretide)TFC-2607-R9099Janoshik2026-Q399.625.47Buyer-sourced0PASS
AX-2026-042217SemaglutideTFC-2604-X9037PeptideMeter2026-Q398.954.6196.9Buyer-sourced0PASS
AX-2026-042214SemaglutideTFC-2604-X9037Kestrel2026-Q399.874.66103.1Laboratory-retained0PASS
AX-2026-042264Humanin (HNG)TFC-2605-U1300Nordanalyt2026-Q399.626.6789.5Buyer-sourced1MARGINAL