AssayIndex

AX-2025-019394

CJC-1295 (no DAC) · 2 mg declared · Shenzhen Hybio Pharmaceutical Co., Ltd. · lot HYB-2504-N7248

PASSPURITY ONLY
Report ID
AX-2025-019394
Compound
CJC-1295 (no DAC)
Compound class
Growth-hormone axis peptides
Supplier
HYB — Shenzhen Hybio Pharmaceutical Co., Ltd.
Batch / lot
HYB-2504-N7248
Declared label claim
2mg
Laboratory
PeptideMeter
Assay date
20 Sep 2025
Submitted
04 Oct 2025
Quarter
2025-Q3
Submitter
f.okafor
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm99.93% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 2.0PASS
Largest single impurityRP-HPLC — des-Tyr1 (−163 Da)0.04% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.32%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography4.91%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.31%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite cake, partial shrinkage from vial wallwhite to off-white intact cakeFAIL
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.892.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient12.04min12.07 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.070.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²60,438≥ 20,000PASS
Resolution to nearest impurityvs deamidated (+1 Da)1.12no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02282456468469128 CJC-1295 (no DAC)12.04 min · 99.93 % 11.54 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 60,438, and skew follows the reported asymmetry factor of 1.07. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.04 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1CJC-1295 (no DAC) — main peak12.044,856,90899.93
2des-Tyr1 (−163 Da)11.541,9440.04-163.063
3deamidated (+1 Da)11.821,4580.03+0.984
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.7399.93divergence +0.46 pp vs batch median
Total impurities (% area)0.270.07
Largest single impurity (% area)not stated0.04
Water (%)1.94.32
Counter-ion (%)not stated4.91
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 8 d) → assay. Submitter did not handle the vial.
Assay date
20 Sep 2025
Submitted to the index
04 Oct 2025
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

aib_coupling
Hindered couplings are where a synthesis loses purity, and the deletion products they leave are the first thing to look for. On this record they are not there in quantity.
buyer_sourced
An independently purchased vial from the same lot would convert this record from indicative to decisive. Buyer-sourced material is roughly 87 % of the index and it should be all of it.
Section 7

Related records

Same batch — lot HYB-2504-N7248 n=9

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019391HYB-2504-N7248Medutest2025-Q399.484.27Buyer-sourced0PASS
AX-2025-019392HYB-2504-N7248Nordanalyt2025-Q399.254.09105.5Buyer-sourced0PASS
AX-2025-019393HYB-2504-N7248Janoshik2025-Q399.244.00Buyer-sourced0PASS
AX-2025-019395HYB-2504-N7248Janoshik2025-Q399.514.1194.1Buyer-sourced0PASS
AX-2025-019396HYB-2504-N7248Janoshik2025-Q399.214.65100.4Buyer-sourced0PASS
AX-2025-019397HYB-2504-N7248VendorInvestigate2025-Q398.894.10Buyer-sourced0PASS
AX-2025-019398HYB-2504-N7248Nordanalyt2025-Q399.274.17106.6Buyer-sourced0PASS
AX-2025-019399HYB-2504-N7248Janoshik2025-Q399.304.35Buyer-sourced0PASS
Other recent CJC-1295 (no DAC) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042942MKMMKM-2603-V3346Janoshik2026-Q399.523.43Supplier-supplied0PASS
AX-2026-041599QSCQSC-2606-V7416VendorInvestigate2026-Q397.963.52Buyer-sourced1FAIL
AX-2026-042784GGPepsGGPE-2606-E1234Medutest2026-Q398.274.55Buyer-sourced0PASS
AX-2026-042939MKMMKM-2603-V3346PeptideMeter2026-Q399.443.39Buyer-sourced0PASS
AX-2026-041601QSCQSC-2606-V7416Kestrel2026-Q398.334.10Buyer-sourced1MARGINAL
AX-2026-042945MKMMKM-2603-V3346PeptideMeter2026-Q399.393.54Laboratory-retained0PASS
AX-2026-042786GGPepsGGPE-2606-E1234Janoshik2026-Q398.223.77Buyer-sourced0PASS
AX-2026-041602QSCQSC-2606-V7416VendorInvestigate2026-Q398.363.38101.8Buyer-sourced1MARGINAL
Other recent HYB records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042083MOTS-cHYB-2606-D7858Medutest2026-Q399.932.02Buyer-sourced0PASS
AX-2026-042090MOTS-cHYB-2606-D7858Janoshik2026-Q399.572.36Buyer-sourced1FAIL
AX-2026-042084MOTS-cHYB-2606-D7858Janoshik2026-Q399.282.79107.3Buyer-sourced0PASS
AX-2026-042087MOTS-cHYB-2606-D7858Janoshik2026-Q399.543.05Buyer-sourced0PASS
AX-2026-042085MOTS-cHYB-2606-D7858Janoshik2026-Q399.512.31Buyer-sourced0PASS
AX-2026-042088MOTS-cHYB-2606-D7858PeptideMeter2026-Q399.222.21Buyer-sourced0PASS
AX-2026-042086MOTS-cHYB-2606-D7858Janoshik2026-Q399.933.02Buyer-sourced1MARGINAL