AssayIndex

AX-2025-020358

5-Amino-1MQ · 100 mg declared · Xi'an Mokemei Biotechnology Co., Ltd. · lot MKM-2503-H3929

FAILIDENTITY CONSISTENT
Report ID
AX-2025-020358
Compound
5-Amino-1MQ
Compound class
Non-peptide adjuncts
Supplier
MKM — Xi'an Mokemei Biotechnology Co., Ltd.
Batch / lot
MKM-2503-H3929
Declared label claim
100mg
Laboratory
Medutest
Assay date
22 Aug 2025
Submitted
29 Aug 2025
Quarter
2025-Q3
Submitter
h.erdogan
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm99.57% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.43% area≤ 2.0PASS
Largest single impurityRP-HPLC — 5-nitro-1MQ (unreduced precursor, +30 Da)0.21% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula285.9967DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)285.9998DaNOT TESTED
Mass accuracyobserved vs theoretical+10.7ppm± 10FAIL
Total peptide contentby difference from the gravimetric mass balance51.77%w/wNOT TESTED
Target-compound contenttotal peptide content × purity51.55%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen202.52mg100 mg declaredNOT TESTED
Recovered target peptidegross fill × target content104.399mg100 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim104.4%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate5.36%≤ 10.0PASS
Counter-ion (iodide)anion-exchange ion chromatography42.73%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.14%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.612.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient4.49min4.59 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.100.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²42,111≥ 20,000PASS
Resolution to nearest impurityvs free iodide (counter-ion, by IC)0.00no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

05023100471507020094 5-Amino-1MQ4.49 min · 99.57 % 5.06 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 42,111, and skew follows the reported asymmetry factor of 1.10. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.21 % impurity against a 99.57 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
15-Amino-1MQ — main peak4.494,839,41199.57
25-nitro-1MQ (unreduced precursor, +30 Da)5.0610,2070.21+29.974
3free iodide (counter-ion, by IC)4.496,3180.130.000
48-amino regioisomer4.672,4300.050.000
51-methylquinolinium (des-amino, −15 Da)4.221,9440.04-15.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 285.9967 Da, computed from C10H11N2+ · I−. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250275300325350375 [M+1H]1+287.01 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 285.9998 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
1+287.0040287.00710.0031100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer5.36
Counter-ion (iodide)ion chromatography42.73
Residual solvent + inorganic residueestimated0.14
Total peptide contentby difference51.77
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.8399.57divergence +0.25 pp vs batch median
Total impurities (% area)not stated0.43
Largest single impurity (% area)not stated0.21
Water (%)4.25.36
Counter-ion (%)not stated42.73
Peptide content (%w/w)not stated51.77
Endotoxin (EU/mg)0.64not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 4 d) → laboratory (courier, dry ice, 8 d) → assay.
Assay date
22 Aug 2025
Submitted to the index
29 Aug 2025
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.57 % should be read as a band, and the band is still comfortably above the class specification.
mass_defect
Mass-defect reasoning narrows this quickly. Very few plausible modifications of 5-Amino-1MQ would produce a shift in the direction and magnitude observed, and the ones that would are all in the named-impurity table.
chain_custody
Custody from checkout to injection is documented on this record. Provenance plus custody is what makes a single result generalise past the vial it came from.
peak_integrator
Anyone comparing this purity figure against a result from a longer method should expect a difference of a few tenths in a predictable direction. The inter-lab page quantifies it per laboratory.
Section 7

Related records

Same batch — lot MKM-2503-H3929 n=10

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020359MKM-2503-H3929Janoshik2025-Q399.405.12Buyer-sourced0FAIL
AX-2025-020360MKM-2503-H3929Nordanalyt2025-Q399.465.57Buyer-sourced0FAIL
AX-2025-020361MKM-2503-H3929Medutest2025-Q399.594.9294.4Buyer-sourced0FAIL
AX-2025-020362MKM-2503-H3929Janoshik2025-Q399.684.85Buyer-sourced0FAIL
AX-2025-020363MKM-2503-H3929Janoshik2025-Q399.685.5295.1Buyer-sourced0FAIL
AX-2025-020364MKM-2503-H3929PeptideMeter2025-Q399.525.49Buyer-sourced0FAIL
AX-2025-020365MKM-2503-H3929Kestrel2025-Q399.865.3797.3Buyer-sourced0FAIL
AX-2025-020366MKM-2503-H3929Janoshik2025-Q399.015.45104.3Buyer-sourced0FAIL
AX-2025-020367MKM-2503-H3929Janoshik2025-Q399.705.09106.9Buyer-sourced0FAIL
Other recent 5-Amino-1MQ records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043050KPKP-2511-W5347Janoshik2026-Q299.354.16105.5Buyer-sourced0FAIL
AX-2026-043044KPKP-2511-W5347PeptideMeter2026-Q299.614.1590.9Buyer-sourced0FAIL
AX-2026-043052KPKP-2511-W5347Medutest2026-Q299.454.23105.5Buyer-sourced1FAIL
AX-2026-043045KPKP-2511-W5347Janoshik2026-Q299.474.08Buyer-sourced0FAIL
AX-2026-043043KPKP-2511-W5347Janoshik2026-Q299.584.16101.1Buyer-sourced0FAIL
AX-2026-042869GGPepsGGPE-2512-M2434Kestrel2026-Q299.554.65103.9Buyer-sourced0FAIL
AX-2026-042868GGPepsGGPE-2512-M2434PeptideMeter2026-Q299.324.3988.5Buyer-sourced1FAIL
AX-2026-043047KPKP-2511-W5347Janoshik2026-Q299.684.17104.0Supplier-supplied0FAIL
Other recent MKM records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042942CJC-1295 (no DAC)MKM-2603-V3346Janoshik2026-Q399.523.43Supplier-supplied0PASS
AX-2026-043019AdipotideMKM-2606-K5012Janoshik2026-Q397.615.77105.1Buyer-sourced0PASS
AX-2026-042939CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.443.39Buyer-sourced0PASS
AX-2026-043020AdipotideMKM-2606-K5012Medutest2026-Q397.735.74Buyer-sourced0PASS
AX-2026-043022AdipotideMKM-2606-K5012Kestrel2026-Q397.696.33106.9Buyer-sourced0PASS
AX-2026-043023AdipotideMKM-2606-K5012Medutest2026-Q397.485.56103.7Supplier-supplied0PASS
AX-2026-042945CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.393.54Laboratory-retained0PASS
AX-2026-042938CJC-1295 (no DAC)MKM-2603-V3346Nordanalyt2026-Q399.473.6795.0Buyer-sourced0PASS