AssayIndex

AX-2025-020568

Retatrutide · 30 mg declared · Shanghai Sigma-Audley New Material Technology Co., Ltd. · lot SSA-2508-N7334

MARGINALPURITY ONLY
Report ID
AX-2025-020568
Compound
Retatrutide
Compound class
Incretin analogues and co-agonists
Supplier
SSA — Shanghai Sigma-Audley New Material Technology Co., Ltd.
Batch / lot
SSA-2508-N7334
Declared label claim
30mg
Laboratory
Janoshik Analytical
Assay date
12 Aug 2025
Submitted
26 Aug 2025
Quarter
2025-Q3
Submitter
peak_integrator
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the incretin analogues and co-agonists class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm97.87% area≥ 96.5PASS
Total impuritiesRP-HPLC, sum of reported peaks2.13% area≤ 3.5PASS
Largest single impurityRP-HPLC — C18 diacid regioisomer1.13% area≤ 1.00FAIL
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance86.91%w/wNOT TESTED
Target-compound contenttotal peptide content × purity85.06%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen34.62mg30 mg declaredNOT TESTED
Recovered target peptidegross fill × target content29.448mg30 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim98.2%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate4.13%≤ 8.0PASS
Counter-ion (TFA)anion-exchange ion chromatography8.53%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.43%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration2.812.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient21.55min20.71 ± 0.50 (normalised)FAIL
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.230.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²60,326≥ 20,000PASS
Resolution to nearest impurityvs [D-Aib2]-diastereomer0.61no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01158231634744632 Retatrutide21.55 min · 97.87 % 22.1323.9619.63 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 60,326, and skew follows the reported asymmetry factor of 1.23. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 1.13 % impurity against a 97.87 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Retatrutide — main peak21.554,756,78597.87
2C18 diacid regioisomer22.1354,9221.130.000
3aspartimide (−18 Da)22.2633,0500.68-18.011
4incomplete Fmoc removal (+222 Da)23.969,2350.19+222.068
5truncated (5-39)19.633,8880.08-428.201
6[D-Aib2]-diastereomer21.331,4580.030.000
7des-Aib20 analogue21.119720.02-85.053
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer4.13
Counter-ion (TFA)ion chromatography8.53
Residual solvent + inorganic residueestimated0.43
Total peptide contentby difference86.91
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)97.8397.87divergence -0.17 pp vs batch median
Total impurities (% area)2.172.13
Largest single impurity (% area)1.401.13
Water (%)2.54.13
Counter-ion (%)not stated8.53
Peptide content (%w/w)not stated86.91
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 31 d) → laboratory (hand-carried, 3 d) → assay.
Assay date
12 Aug 2025
Submitted to the index
26 Aug 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sec_monomer
Where the close neighbour is an aggregate rather than a related substance, size exclusion separates them trivially and reverse phase never will.
valley_drop
The index's position is that the integration convention must be stated, not that any particular convention must be used. Both are defensible; only one can be reported and it should be named.
Section 7

Related records

Same batch — lot SSA-2508-N7334 n=4

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020569SSA-2508-N7334Janoshik2025-Q398.274.21102.6Supplier-supplied1MARGINAL
AX-2025-020570SSA-2508-N7334Janoshik2025-Q398.124.13Buyer-sourced0PASS
AX-2025-020571SSA-2508-N7334Janoshik2025-Q397.874.42Supplier-supplied0PASS
Other recent Retatrutide records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042437HomopeptideHOMO-2605-V4718Nordanalyt2026-Q398.683.67102.8Buyer-sourced0PASS
AX-2026-043095KPKP-2607-H5774Janoshik2026-Q395.815.48105.2Buyer-sourced0FAIL
AX-2026-042282TFCTFC-2608-J1156Janoshik2026-Q398.544.27Buyer-sourced0PASS
AX-2026-043094KPKP-2607-H5774PeptideMeter2026-Q396.326.40Buyer-sourced0FAIL
AX-2026-042441HomopeptideHOMO-2605-V4718Medutest2026-Q398.934.22Buyer-sourced0PASS
AX-2026-041427QYBQYB-2604-B4920PeptideMeter2026-Q397.932.45101.7Buyer-sourced0PASS
AX-2026-041786ASYASY-{CAT}-2288VendorInvestigate2026-Q398.786.59Buyer-sourced0PASS
AX-2026-041428QYBQYB-2604-B4920Janoshik2026-Q398.353.20Laboratory-retained0PASS
Other recent SSA records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043135BPC-157SSA-2601-N6863Nordanalyt2026-Q298.164.6692.8Buyer-sourced1MARGINAL
AX-2026-043160GHK-CuSSA-2604-V7731Janoshik2026-Q298.014.0291.8Buyer-sourced0PASS
AX-2026-043157GHK-CuSSA-2604-V7731Medutest2026-Q299.195.14Supplier-supplied0PASS
AX-2026-043141BPC-157SSA-2601-N6863Janoshik2026-Q298.064.0694.6Buyer-sourced1MARGINAL
AX-2026-043154GHK-CuSSA-2604-V7731PeptideMeter2026-Q297.824.82101.6Buyer-sourced0PASS
AX-2026-043137BPC-157SSA-2601-N6863PeptideMeter2026-Q298.174.14Buyer-sourced1MARGINAL
AX-2026-043162GHK-CuSSA-2604-V7731Janoshik2026-Q298.504.36Supplier-supplied0PASS
AX-2026-043134BPC-157SSA-2601-N6863Medutest2026-Q297.894.01Buyer-sourced1FAIL