AssayIndex

AX-2025-020845

KPV · 20 mg declared · Chinese Peptide Company Co., Ltd. · lot CPC-2502-M2176

FAILIDENTITY CONSISTENT
Report ID
AX-2025-020845
Compound
KPV
Compound class
Tissue-repair and immunomodulatory peptides
Supplier
CPC — Chinese Peptide Company Co., Ltd.
Batch / lot
CPC-2502-M2176
Declared label claim
20mg
Laboratory
VendorInvestigate
Assay date
12 Aug 2025
Submitted
16 Aug 2025
Quarter
2025-Q3
Submitter
chain_custody
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the tissue-repair and immunomodulatory peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 32 min gradient, 214 nm98.58% area≥ 99.0FAIL
Total impuritiesRP-HPLC, sum of reported peaks1.42% area≤ 1.0FAIL
Largest single impurityRP-HPLC — Lys-Pro dipeptide (−99 Da)0.91% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula342.2267DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)342.2264DaNOT TESTED
Mass accuracyobserved vs theoretical-0.8ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate3.63%≤ 10.0PASS
Counter-ion (acetate)anion-exchange ion chromatography12.87%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.55%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureFaint haze, clearing on standingclear, no visible particulatesFAIL
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.902.5 – 8.0PASS
Retention time (observed)RP-HPLC, 32 min gradient5.44min5.56 ± 0.20 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.000.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²63,649≥ 20,000PASS
Resolution to nearest impurityvs diketopiperazine (−18 Da)1.81no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

05292105841587621168 KPV5.44 min · 98.58 % 5.06 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 32 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 63,649, and skew follows the reported asymmetry factor of 1.00. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.91 % impurity against a 98.58 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1KPV — main peak5.444,791,29498.58
2Lys-Pro dipeptide (−99 Da)5.0644,2290.91-99.068
3acetyl-KPV (+42 Da)5.7616,5250.34+42.011
4Pro-Val dipeptide (−128 Da)4.974,8600.10-128.095
5diketopiperazine (−18 Da)5.603,4020.07-18.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 342.2267 Da, computed from C16H30N4O4. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100300325350375400425 [M+1H]1+343.23 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 342.2264 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
1+343.2340343.2337-0.0003100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.4498.58divergence +0.13 pp vs batch median
Total impurities (% area)not stated1.42
Largest single impurity (% area)not stated0.91
Water (%)2.33.63
Counter-ion (%)not stated12.87
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 1 d) → laboratory (courier, dry ice, 7 d) → assay.
Assay date
12 Aug 2025
Submitted to the index
16 Aug 2025
Laboratory
VendorInvestigate, Riga, Latvia
Method basis
32 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

spec_vs_result
The index specification is a threshold the index chose. A result below it is a measurement below a decision, not a regulatory status and not a safety statement. What it does establish is that this vial is not what the class specification describes.
ms_confirm
A reference standard on the same sequence would upgrade this from a good mass to a traceable one. The distinction matters where a result is going to be cited rather than merely read.
ppm_error
Instrument was evidently in calibration on the day. A run of results at this accuracy across a laboratory's sequence is the background against which an excursion becomes interpretable.
schema_v2
Both the theoretical and the observed monoisotopic mass are in the published dataset, so the ppm figure can be re-derived rather than trusted. That is the intent of publishing both.
Section 7

Related records

Same batch — lot CPC-2502-M2176 n=11

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020839CPC-2502-M2176Nordanalyt2025-Q398.142.79Buyer-sourced0FAIL
AX-2025-020840CPC-2502-M2176Janoshik2025-Q398.193.10Buyer-sourced0FAIL
AX-2025-020841CPC-2502-M2176Janoshik2025-Q398.313.2091.1Buyer-sourced0FAIL
AX-2025-020842CPC-2502-M2176Medutest2025-Q398.833.64Supplier-supplied1FAIL
AX-2025-020843CPC-2502-M2176Janoshik2025-Q398.083.15Buyer-sourced0FAIL
AX-2025-020844CPC-2502-M2176Medutest2025-Q398.603.40Buyer-sourced0FAIL
AX-2025-020846CPC-2502-M2176PeptideMeter2025-Q398.232.96Buyer-sourced0FAIL
AX-2025-020847CPC-2502-M2176Janoshik2025-Q399.253.41102.8Supplier-supplied1FAIL
AX-2025-020848CPC-2502-M2176Medutest2025-Q398.133.3297.4Buyer-sourced0FAIL
AX-2025-020849CPC-2502-M2176Medutest2025-Q398.492.77105.0Buyer-sourced1FAIL
Other recent KPV records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042742GGPepsGGPE-2511-K1569Janoshik2026-Q298.405.09Buyer-sourced0FAIL
AX-2026-042259TFCTFC-2508-M9624Janoshik2026-Q199.933.3889.4Buyer-sourced1FAIL
AX-2026-042078HYBHYB-2511-P7317Nordanalyt2026-Q199.593.9298.8Buyer-sourced0PASS
AX-2026-042262TFCTFC-2508-M9624Janoshik2026-Q199.893.3292.2Buyer-sourced0FAIL
AX-2026-042260TFCTFC-2508-M9624PeptideMeter2026-Q199.932.8999.2Buyer-sourced0FAIL
AX-2026-042079HYBHYB-2511-P7317Janoshik2026-Q199.685.6794.7Buyer-sourced0FAIL
AX-2026-042257TFCTFC-2508-M9624Janoshik2026-Q199.542.8195.6Buyer-sourced0FAIL
AX-2026-042261TFCTFC-2508-M9624Medutest2026-Q199.933.2097.1Buyer-sourced0FAIL
Other recent CPC records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043319BPC-157CPC-2602-W1610Medutest2026-Q398.822.88103.5Buyer-sourced2MARGINAL
AX-2026-043295LiraglutideCPC-2602-G9942Janoshik2026-Q397.345.17106.3Buyer-sourced0FAIL
AX-2026-043288TirzepatideCPC-2607-L1516Janoshik2026-Q396.895.11101.1Laboratory-retained0FAIL
AX-2026-043327N-Acetyl Semax AmideCPC-2602-D1905Nordanalyt2026-Q399.055.6790.6Buyer-sourced1FAIL
AX-2026-043328N-Acetyl Semax AmideCPC-2602-D1905Janoshik2026-Q399.496.83100.9Supplier-supplied0PASS
AX-2026-043257L-CarnosineCPC-2603-G9615VendorInvestigate2026-Q398.2010.41102.2Buyer-sourced0FAIL
AX-2026-043297LiraglutideCPC-2602-G9942Janoshik2026-Q397.014.95103.5Buyer-sourced0FAIL
AX-2026-043331N-Acetyl Semax AmideCPC-2602-D1905Janoshik2026-Q399.466.22Supplier-supplied0PASS