AssayIndex

AX-2026-041706

BPC-157 · 10 mg declared · Thermo Fisher Scientific (China) Co., Ltd. · lot TFS-{CAT}-9814

PASSVERIFIED
Report ID
AX-2026-041706
Compound
BPC-157
Compound class
Tissue-repair and immunomodulatory peptides
Supplier
TFS — Thermo Fisher Scientific (China) Co., Ltd.
Batch / lot
TFS-{CAT}-9814
Declared label claim
10mg
Laboratory
Janoshik Analytical
Assay date
26 Apr 2026
Submitted
08 May 2026
Quarter
2026-Q2
Submitter
freeze_thaw
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the tissue-repair and immunomodulatory peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.34% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.66% area≤ 2.0PASS
Largest single impurityRP-HPLC — [D-Val]-diastereomer0.39% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula1418.7093DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)1418.7124DaNOT TESTED
Mass accuracyobserved vs theoretical+2.2ppm± 15PASS
Total peptide contentby difference from the gravimetric mass balance86.65%w/wNOT TESTED
Target-compound contenttotal peptide content × purity86.08%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen10.98mg10 mg declaredNOT TESTED
Recovered target peptidegross fill × target content9.452mg10 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim94.5%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate5.04%≤ 10.0PASS
Counter-ion (acetate)anion-exchange ion chromatography7.49%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.82%NOT TESTED
Endotoxinkinetic chromogenic LAL0.29EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite to pale-yellow cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureFaint haze, clearing on standingclear, no visible particulatesFAIL
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.372.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient9.63min9.62 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.150.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²72,539≥ 20,000PASS
Resolution to nearest impurityvs [D-Val]-diastereomer0.96no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

029925983897511967 BPC-1579.63 min · 99.34 % 9.49 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 72,539, and skew follows the reported asymmetry factor of 1.15. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.39 % impurity against a 99.34 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1BPC-157 — main peak9.634,828,23299.34
2[D-Val]-diastereomer9.4918,9550.390.000
3acetylated N-terminus (+42 Da)10.117,2900.15+42.011
4pyroglutamate cyclisation (−17 Da)9.943,4020.07-17.027
5des-Gly truncate (−57 Da)9.291,4580.03-57.021
6BPC-157 arginine-salt artefact9.089720.020.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 1418.7093 Da, computed from C62H98N16O22. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100350550750950115013501550 [M+1H]1+1419.72[M+2H]2+710.36 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 1418.7124 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
3+473.9104473.91140.00108.3
2+710.3619710.36350.001657.5
1+1419.71661419.71970.0031100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer5.04
Counter-ion (acetate)ion chromatography7.49
Residual solvent + inorganic residueestimated0.82
Total peptide contentby difference86.65
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.2999.34divergence 0.00 pp vs batch median
Total impurities (% area)0.710.66
Largest single impurity (% area)not stated0.39
Water (%)2.25.04
Counter-ion (%)not stated7.49
Peptide content (%w/w)not stated86.65
Endotoxin (EU/mg)0.390.29
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Domestic warehouse despatch → submitter (2–8 °C, 17 d) → laboratory (courier, cold pack, 3 d) → assay.
Assay date
26 Apr 2026
Submitted to the index
08 May 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

charge_envelope
Base peak lands where the charge-state arithmetic says it should for a species of this mass. That agreement is a check on the deconvolution rather than on the material, and it passes.
gradient_25
The resolution figure sits in the system-suitability block with no PASS or FAIL beside it. That is deliberate: the index reports it and adjudicates nothing against it.
Section 7

Related records

Same batch — lot TFS-{CAT}-9814 n=7

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041702TFS-{CAT}-9814Medutest2026-Q299.084.95Buyer-sourced0PASS
AX-2026-041703TFS-{CAT}-9814PeptideMeter2026-Q299.354.03101.3Buyer-sourced0PASS
AX-2026-041704TFS-{CAT}-9814Janoshik2026-Q299.243.9196.3Buyer-sourced0PASS
AX-2026-041705TFS-{CAT}-9814PeptideMeter2026-Q299.254.5192.1Buyer-sourced0PASS
AX-2026-041707TFS-{CAT}-9814Medutest2026-Q299.294.1789.7Buyer-sourced1MARGINAL
AX-2026-041708TFS-{CAT}-9814Medutest2026-Q299.394.21Buyer-sourced0PASS
Other recent BPC-157 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043319CPCCPC-2602-W1610Medutest2026-Q398.822.88103.5Buyer-sourced2MARGINAL
AX-2026-041766TFSTFS-{CAT}-1156Janoshik2026-Q399.546.34Buyer-sourced1MARGINAL
AX-2026-043445BCHBCH-2603-G4350Nordanalyt2026-Q398.424.8793.6Buyer-sourced1MARGINAL
AX-2026-043440BCHBCH-2603-G4350VendorInvestigate2026-Q398.614.11Buyer-sourced1MARGINAL
AX-2026-043442BCHBCH-2603-G4350Janoshik2026-Q398.654.78Buyer-sourced1MARGINAL
AX-2026-043449BCHBCH-2603-G4350Kestrel2026-Q399.744.9291.3Supplier-supplied2MARGINAL
AX-2026-043448BCHBCH-2603-G4350Janoshik2026-Q398.554.69106.9Buyer-sourced1MARGINAL
AX-2026-043318CPCCPC-2602-W1610VendorInvestigate2026-Q398.473.12104.1Buyer-sourced1MARGINAL
Other recent TFS records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041681CJC-1295 with DACTFS-{CAT}-9675PeptideMeter2026-Q398.823.67Buyer-sourced0PASS
AX-2026-041766BPC-157TFS-{CAT}-1156Janoshik2026-Q399.546.34Buyer-sourced1MARGINAL
AX-2026-041682CJC-1295 with DACTFS-{CAT}-9675Nordanalyt2026-Q398.943.24Buyer-sourced0PASS
AX-2026-041683CJC-1295 with DACTFS-{CAT}-9675Medutest2026-Q398.683.4697.0Buyer-sourced0PASS
AX-2026-041765BPC-157TFS-{CAT}-1156Janoshik2026-Q399.796.01Buyer-sourced0PASS
AX-2026-041680CJC-1295 with DACTFS-{CAT}-9675Medutest2026-Q399.182.85100.4Buyer-sourced0PASS
AX-2026-041691SemaglutideTFS-{CAT}-9744Janoshik2026-Q298.316.0791.4Buyer-sourced0PASS
AX-2026-041700SS-31 (Elamipretide)TFS-{CAT}-1142Medutest2026-Q299.752.2796.3Buyer-sourced0PASS