AssayIndex

HOMO-2509-F5826

Semaglutide · 3 mg declared · Hunan Aslsen Technology Co., Ltd. · manufactured 27 Sep 2025

CHARACTERISED
Lot code
HOMO-2509-F5826
Supplier
Homopeptide — Hunan Aslsen Technology Co., Ltd.
Compound
Semaglutide
Compound class
Incretin analogues and co-agonists
Declared label claim
3mg
Manufacture date
27 Sep 2025
Index quarter
2025-Q4
Independent assays
11
Laboratories involved
Janoshik, Nordanalyt, Kestrel, Medutest, PeptideMeter
Provenance mix
Buyer-sourced ×9 · Supplier-supplied ×1 · Laboratory-retained ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 11
Median purity 99.57% n=11
Spread (max − min) 0.83pp n=11
Standard deviation 0.297pp n=11
96.397.097.698.398.999.6100.2This lot (HOMO-2509-F5826)This lot (HOMO-2509-F5826): Q1 99.35, median 99.57, Q3 99.81, n=11n=11All SemaglutideAll Semaglutide: Q1 98.38, median 98.89, Q3 99.34, n=768outlier 96.58outlier 96.69n=768 Purity (% area)
Figure 1. This lot's independent purity results against the whole Semaglutide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 97.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 11

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019850HOMO-2509-F5826Janoshik2025-Q499.514.7293.1Buyer-sourced1MARGINAL
AX-2025-019851HOMO-2509-F5826Nordanalyt2025-Q499.354.47101.9Laboratory-retained0PASS
AX-2025-019852HOMO-2509-F5826Kestrel2025-Q499.934.40103.9Supplier-supplied0PASS
AX-2025-019853HOMO-2509-F5826Medutest2025-Q499.684.33Buyer-sourced0PASS
AX-2025-019854HOMO-2509-F5826Medutest2025-Q499.934.34Buyer-sourced0PASS
AX-2025-019855HOMO-2509-F5826Nordanalyt2025-Q499.574.90Buyer-sourced0PASS
AX-2025-019856HOMO-2509-F5826Kestrel2025-Q499.824.88Buyer-sourced1FAIL
AX-2025-019857HOMO-2509-F5826Nordanalyt2025-Q499.144.9596.2Buyer-sourced0PASS
AX-2025-019858HOMO-2509-F5826Janoshik2025-Q499.364.8489.6Buyer-sourced1MARGINAL
AX-2026-042512HOMO-2509-F5826PeptideMeter2025-Q499.104.25Buyer-sourced1MARGINAL
AX-2025-019859HOMO-2509-F5826Medutest2025-Q499.794.99106.3Buyer-sourced0PASS
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik299.51, 99.3699.4430min+0.0099.44
Nordanalyt399.35, 99.57, 99.1499.3535min+0.0299.33
Kestrel299.93, 99.8299.8815min+0.2499.64
Medutest399.68, 99.93, 99.7999.7925min+0.0899.71
PeptideMeter199.1099.1028min-0.0599.15

This lot contributes 10 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.51divergence +0.33 pp vs batch median
Total impurities (% area)0.100.49
Largest single impurity (% area)0.040.29
Water (%)3.04.72
Counter-ion (%)not stated8.50
Peptide content (%w/w)not stated86.14
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
deamidated (Asn→Asp, +1 Da)11 / 110.140.03–0.40
[D-Aib8]-diastereomer9 / 110.070.02–0.23
Met(O) sulfoxide (+16 Da)6 / 110.080.04–0.45
des-His1 truncate (−137 Da)6 / 110.060.02–0.06
semaglutide dimer5 / 110.130.04–0.18
C18 diacid mono-ester3 / 110.020.02–0.03
des-AEEA semaglutide (−145 Da)2 / 110.030.02–0.04
Section 7

What this rollup does not establish