AssayIndex

MKM-2602-M2972

CJC-1295 with DAC · 10 mg declared · Xi'an Mokemei Biotechnology Co., Ltd. · manufactured 16 Feb 2026

SINGLE TEST
Lot code
MKM-2602-M2972
Supplier
MKM — Xi'an Mokemei Biotechnology Co., Ltd.
Compound
CJC-1295 with DAC
Compound class
Growth-hormone axis peptides
Declared label claim
10mg
Manufacture date
16 Feb 2026
Index quarter
2026-Q1
Independent assays
1
Laboratories involved
PeptideMeter
Provenance mix
Supplier-supplied ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 99.10% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
96.697.297.898.499.099.6100.2All CJC-1295 with DACAll CJC-1295 with DAC: Q1 98.44, median 98.95, Q3 99.25, n=121outlier 96.83outlier 96.99outlier 97.16outlier 97.20outlier 97.21n=121 Purity (% area)
Figure 1. This lot's independent purity results against the whole CJC-1295 with DAC record set in the index. The vertical line is the index acceptance specification for the growth-hormone axis peptides class, 97.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042922MKM-2602-M2972PeptideMeter2026-Q199.103.2798.6Supplier-supplied0PASS
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
PeptideMeter199.1099.1028min-0.0599.15

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.5999.10divergence +0.49 pp vs batch median
Total impurities (% area)0.410.90
Largest single impurity (% area)not stated0.47
Water (%)1.83.27
Counter-ion (%)not stated4.44
Peptide content (%w/w)not stated91.83
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
hydrolysed maleimide (+18 Da)1 / 10.47
maleimide dimer1 / 10.28
mod-GRF (1-29) (−279 Da)1 / 10.08
deamidated (+1 Da)1 / 10.07
Section 7

What this rollup does not establish