AssayIndex

SSA-2508-B6436

Vilon · 10 mg declared · Shanghai Sigma-Audley New Material Technology Co., Ltd. · manufactured 18 Aug 2025

CHARACTERISED
Lot code
SSA-2508-B6436
Supplier
SSA — Shanghai Sigma-Audley New Material Technology Co., Ltd.
Compound
Vilon
Compound class
Short bioregulator peptides
Declared label claim
10mg
Manufacture date
18 Aug 2025
Index quarter
2025-Q3
Independent assays
3
Laboratories involved
Nordanalyt, Janoshik, Kestrel
Provenance mix
Buyer-sourced ×3
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 3
Median purity 99.15% n=3
Spread (max − min) 0.13pp n=3
Standard deviation 0.070pp n=3
98.098.498.799.199.499.7100.1This lot (SSA-2508-B6436)This lot (SSA-2508-B6436): Q1 99.14, median 99.15, Q3 99.21, n=3n=3All VilonAll Vilon: Q1 99.15, median 99.65, Q3 99.93, n=17n=17 Purity (% area)
Figure 1. This lot's independent purity results against the whole Vilon record set in the index. The vertical line is the index acceptance specification for the short bioregulator peptides class, 99.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 3

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020539SSA-2508-B6436Nordanalyt2025-Q399.265.49Buyer-sourced0FAIL
AX-2025-020540SSA-2508-B6436Janoshik2025-Q399.135.9397.9Buyer-sourced1FAIL
AX-2025-020541SSA-2508-B6436Kestrel2025-Q399.156.2193.5Buyer-sourced0FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Nordanalyt199.2699.2635min+0.0299.24
Janoshik199.1399.1330min+0.0099.13
Kestrel199.1599.1515min+0.2498.91

This lot contributes 3 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.5199.26divergence +0.36 pp vs batch median
Total impurities (% area)0.490.74
Largest single impurity (% area)0.270.37
Water (%)3.85.49
Counter-ion (%)8.317.56
Peptide content (%w/w)87.3not determined
Endotoxin (EU/mg)0.58not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
diketopiperazine (−18 Da)3 / 30.370.11–0.43
free lysine (−129 Da)3 / 30.160.08–0.18
free glutamic acid (−128 Da)3 / 30.120.11–0.54
Lys-Glu-Lys tripeptide (+128 Da)3 / 30.120.10–0.14
Section 7

What this rollup does not establish