AssayIndex
Cross-section

GHRP-2 by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for GHRP-2, with a class minimum gradient of 15 min, the method is a live explanation.

110 recordsmedian 99.28 %spec 99.0 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik4930minHigh99.48+0.0099.48ADEQUATE
PeptideMeter2028minHigh99.21-0.0599.26ADEQUATE
Medutest1625minUnit99.28+0.0899.20ADEQUATE
VendorInvestigate1132minHigh98.80-0.1198.91ADEQUATE
Nordanalyt835minHigh99.43+0.0299.41ADEQUATE
Kestrel6 n=615minUnit99.75+0.2499.52ADEQUATE
97.197.698.198.699.199.6100.1JanoshikJanoshik: Q1 99.06, median 99.48, Q3 99.79, n=49n=49PeptideMeterPeptideMeter: Q1 99.00, median 99.21, Q3 99.38, n=20outlier 98.14n=20MedutestMedutest: Q1 99.11, median 99.28, Q3 99.61, n=16n=16VendorInvestigateVendorInvestigate: Q1 98.48, median 98.80, Q3 99.14, n=11outlier 97.35n=11NordanalytNordanalyt: Q1 98.68, median 99.43, Q3 99.93, n=8n=8KestrelKestrel: Q1 99.63, median 99.75, Q3 99.90, n=6outlier 98.93n=6 Purity (% area)
Figure. GHRP-2 purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.