MK-677 (Ibutamoren mesylate) by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for MK-677 (Ibutamoren mesylate), with a class minimum gradient of 15 min, the method is a live explanation.

143 recordsmedian 99.49 %spec 98.5 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik6030minHigh99.50+0.0099.50ADEQUATE
PeptideMeter3328minHigh99.45-0.0599.50ADEQUATE
Medutest2025minUnit99.61+0.0899.53ADEQUATE
Kestrel1215minUnit99.73+0.2499.50ADEQUATE
Nordanalyt1035minHigh99.41+0.0299.39ADEQUATE
VendorInvestigate832minHigh99.43-0.1199.54ADEQUATE
97.798.198.598.999.399.7100.1JanoshikJanoshik: Q1 99.10, median 99.50, Q3 99.75, n=60n=60PeptideMeterPeptideMeter: Q1 99.12, median 99.45, Q3 99.79, n=33outlier 97.95n=33MedutestMedutest: Q1 99.26, median 99.61, Q3 99.93, n=20n=20VendorInvestigateVendorInvestigate: Q1 98.98, median 99.43, Q3 99.74, n=8n=8NordanalytNordanalyt: Q1 99.27, median 99.41, Q3 99.72, n=10n=10KestrelKestrel: Q1 99.17, median 99.73, Q3 99.93, n=12outlier 97.90n=12 Purity (% area)
Figure. MK-677 (Ibutamoren mesylate) purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.