AssayIndex

AX-2024-004142

GHRP-6 · 10 mg declared · Wuhan Wansheng Biotechnology Co., Ltd. · lot WWB-2408-E1643

PASSPURITY ONLY
Report ID
AX-2024-004142
Compound
GHRP-6
Compound class
Growth-hormone axis peptides
Supplier
WWB — Wuhan Wansheng Biotechnology Co., Ltd.
Batch / lot
WWB-2408-E1643
Declared label claim
10mg
Laboratory
Janoshik Analytical
Assay date
19 Sep 2024
Submitted
05 Oct 2024
Quarter
2024-Q3
Submitter
so.broberg
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.73% area≥ 99.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.27% area≤ 1.0PASS
Largest single impurityRP-HPLC — oxidised Trp (+16 Da)0.18% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate7.52%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography6.90%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.22%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.202.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient8.63min8.44 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.110.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²45,259≥ 20,000PASS
Resolution to nearest impurityvs [D-Trp]-epimer0.72no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

026975395809210790 GHRP-68.63 min · 99.73 % 8.29 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 45,259, and skew follows the reported asymmetry factor of 1.11. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.18 % impurity against a 99.73 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1GHRP-6 — main peak8.634,847,18799.73
2oxidised Trp (+16 Da)8.298,7490.18+15.995
3des-Lys (−128 Da)8.412,9160.06-128.095
4[D-Trp]-epimer8.519720.020.000
5bis-oxidised Trp (+32 Da)8.054860.01+31.990
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.6699.73divergence -0.06 pp vs batch median
Total impurities (% area)0.340.27
Largest single impurity (% area)0.220.18
Water (%)5.77.52
Counter-ion (%)not stated6.90
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 27 d) → laboratory (courier, dry ice, 4 d) → assay.
Assay date
19 Sep 2024
Submitted to the index
05 Oct 2024
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

aib_coupling
Hindered couplings are where a synthesis loses purity, and the deletion products they leave are the first thing to look for. On this record they are not there in quantity.
tbu_residual
Residual side-chain protection at +56 Da is the classic silent passenger on a high-purity trace. Nothing at that offset above threshold on this record.
coa_template
The document that arrived with this order is on file and its fields are scored on the supplier's documentation rubric. That score describes what a buyer receives, which is the useful version.
Section 7

Related records

Same batch — lot WWB-2408-E1643 n=2

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004143WWB-2408-E1643Janoshik2024-Q399.717.7397.4Laboratory-retained0PASS
Other recent GHRP-6 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042012AMBAMB-2603-S5667Janoshik2026-Q399.375.9088.8Laboratory-retained1MARGINAL
AX-2026-042528HJHJ-2603-R5329VendorInvestigate2026-Q398.691.8795.8Buyer-sourced0FAIL
AX-2026-042015AMBAMB-2603-S5667Janoshik2026-Q399.546.4497.1Buyer-sourced0PASS
AX-2026-042526HJHJ-2603-R5329Medutest2026-Q399.373.06Laboratory-retained0PASS
AX-2026-042527HJHJ-2603-R5329VendorInvestigate2026-Q399.212.7793.2Buyer-sourced0PASS
AX-2026-042525HJHJ-2603-R5329Janoshik2026-Q399.523.2492.0Buyer-sourced0PASS
AX-2026-042013AMBAMB-2603-S5667Kestrel2026-Q399.935.75Buyer-sourced0PASS
AX-2026-042017AMBAMB-2603-S5667Medutest2026-Q399.766.4297.4Buyer-sourced0PASS
Other recent WWB records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041275LiraglutideWWB-2607-X2189Nordanalyt2026-Q399.334.39Buyer-sourced1MARGINAL
AX-2026-041334SemaglutideWWB-2606-N3192Janoshik2026-Q398.934.6299.9Buyer-sourced0PASS
AX-2026-041337SemaglutideWWB-2606-N3192Nordanalyt2026-Q399.523.92Buyer-sourced0PASS
AX-2026-041335SemaglutideWWB-2606-N3192Janoshik2026-Q399.154.2798.9Buyer-sourced0PASS
AX-2026-041271LiraglutideWWB-2607-X2189Medutest2026-Q399.524.5797.4Buyer-sourced1MARGINAL
AX-2026-041328SemaglutideWWB-2606-N3192Janoshik2026-Q398.994.47106.1Buyer-sourced0PASS
AX-2026-041333SemaglutideWWB-2606-N3192Janoshik2026-Q399.184.5190.4Laboratory-retained0PASS
AX-2026-041273LiraglutideWWB-2607-X2189Janoshik2026-Q399.315.52104.8Buyer-sourced1MARGINAL