AssayIndex

AX-2025-018771

MK-677 (Ibutamoren mesylate) · 1000 mg declared · Flourishglobal Peptide Biotech (Chengdu) Co., Ltd. · lot FGP-2502-F7880

FAILIDENTITY CONSISTENT
Report ID
AX-2025-018771
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
FGP — Flourishglobal Peptide Biotech (Chengdu) Co., Ltd.
Batch / lot
FGP-2502-F7880
Declared label claim
1000mg
Laboratory
Janoshik Analytical
Assay date
10 May 2025
Submitted
26 May 2025
Quarter
2025-Q2
Submitter
n.yildiz
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.45% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.55% area≤ 1.5PASS
Largest single impurityRP-HPLC — free base (des-mesylate, −96 Da)0.23% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)624.2187DaNOT TESTED
Mass accuracyobserved vs theoretical+0.9ppm± 10PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.21%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography15.15%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.57%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureFaint haze, clearing on standingclear, no visible particulatesFAIL
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.012.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient13.83min13.86 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.150.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²50,570≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.16no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01745348952346978 MK-677 (Ibutamoren mesylate)13.83 min · 99.45 % 5.6313.87 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 50,570, and skew follows the reported asymmetry factor of 1.15. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.23 % impurity against a 99.45 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak13.834,833,57899.45
2free base (des-mesylate, −96 Da)13.8711,1790.23-96.011
3residual DMF (process solvent)5.637,2900.15-551.000
4O-desmethyl metabolite analogue (−14 Da)13.315,3460.11-14.016
5sulfonamide hydrolysis product (+18 Da)12.972,9160.06+18.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.23[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2187 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.11660.000352.6
1+625.2254625.22600.0006100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.4399.45divergence +0.11 pp vs batch median
Total impurities (% area)0.570.55
Largest single impurity (% area)0.350.23
Water (%)not stated4.21
Counter-ion (%)6.315.15
Peptide content (%w/w)89.6not determined
Endotoxin (EU/mg)0.53not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 14 d) → laboratory (courier, cold pack, 4 d) → assay.
Assay date
10 May 2025
Submitted to the index
26 May 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

diode_array
Photodiode-array spectral homogeneity across the main peak would convert 99.45 % from a good number into a checked one. It is a free measurement on any instrument that already has the detector.
lambda_214
Detection wavelength does not affect a mass determination but it does affect the purity figure sitting next to it. Both are stated on this record, which is the point.
dedupe_logic
Two retail purchases of the same lot from different buyers are genuinely independent. Two aliquots of one purchase are not, and the index does not treat them as such.
valley_drop
free base (des-mesylate, −96 Da) at 0.23 % elutes close enough to the main peak that drop-line and valley-to-valley will not agree. The index prints the resolution figure and applies no criterion to it — how close the nearest impurity sits is a property of the compound and the gradient, not of the system. What matters is that the convention used is stated.
Section 7

Related records

Same batch — lot FGP-2502-F7880 n=7

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-018769FGP-2502-F7880Janoshik2025-Q299.193.93Buyer-sourced0FAIL
AX-2025-018770FGP-2502-F7880Medutest2025-Q299.323.90Buyer-sourced0FAIL
AX-2025-018772FGP-2502-F7880Janoshik2025-Q299.234.5495.0Buyer-sourced0FAIL
AX-2025-018773FGP-2502-F7880PeptideMeter2025-Q299.504.20101.9Buyer-sourced0FAIL
AX-2025-018774FGP-2502-F7880VendorInvestigate2025-Q298.934.8798.0Buyer-sourced0FAIL
AX-2025-018775FGP-2502-F7880PeptideMeter2025-Q299.454.0698.8Buyer-sourced0FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent FGP records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041643SemaglutideFGP-2602-M8547Janoshik2026-Q399.312.79100.7Buyer-sourced0PASS
AX-2026-041638SemaglutideFGP-2602-M8547Janoshik2026-Q399.402.75105.8Buyer-sourced0PASS
AX-2026-041641SemaglutideFGP-2602-M8547PeptideMeter2026-Q398.982.38105.0Buyer-sourced0PASS
AX-2026-041610TirzepatideFGP-2603-L7753Janoshik2026-Q398.812.45101.0Buyer-sourced0PASS
AX-2026-041637SemaglutideFGP-2602-M8547PeptideMeter2026-Q399.402.83Laboratory-retained0PASS
AX-2026-041642SemaglutideFGP-2602-M8547PeptideMeter2026-Q398.782.24Buyer-sourced0PASS
AX-2026-041609TirzepatideFGP-2603-L7753Janoshik2026-Q398.522.0098.0Buyer-sourced0PASS
AX-2026-041636SemaglutideFGP-2602-M8547Nordanalyt2026-Q399.392.17Buyer-sourced0PASS