AssayIndex

AX-2025-019381

MK-677 (Ibutamoren mesylate) · 250 mg declared · Shenzhen Hybio Pharmaceutical Co., Ltd. · lot HYB-2505-M6859

FAILIDENTITY CONSISTENT
Report ID
AX-2025-019381
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
HYB — Shenzhen Hybio Pharmaceutical Co., Ltd.
Batch / lot
HYB-2505-M6859
Declared label claim
250mg
Laboratory
Kestrel Bioanalytical
Assay date
18 Apr 2025
Submitted
08 May 2025
Quarter
2025-Q2
Submitter
Contributor #P-5401
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 15 min gradient, 214 nm99.93% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 1.5PASS
Largest single impurityRP-HPLC — residual DMF (process solvent)0.04% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)624.2275DaNOT TESTED
Mass accuracyobserved vs theoretical+15.1ppm± 10FAIL
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.30%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography16.25%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.41%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration3.912.5 – 8.0PASS
Retention time (observed)RP-HPLC, 15 min gradient7.42min7.48 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.100.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²55,655≥ 20,000PASS
Resolution to nearest impurityvs spiroindane regioisomer1.71no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0350370051050814011 MK-677 (Ibutamoren mesylate)7.42 min · 99.93 % 3.327.64 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 048121620 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 15 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 55,655, and skew follows the reported asymmetry factor of 1.10. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.04 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak7.424,856,90899.93
2residual DMF (process solvent)3.321,9440.04-551.000
3spiroindane regioisomer7.641,4580.030.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.23[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2275 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.12100.004755.7
1+625.2254625.23480.0094100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence +0.03 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)0.050.04
Water (%)3.94.30
Counter-ion (%)not stated16.25
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)0.48not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Domestic warehouse despatch → submitter (2–8 °C, 12 d) → laboratory (courier, cold pack, 10 d) → assay.
Assay date
18 Apr 2025
Submitted to the index
08 May 2025
Laboratory
Kestrel Bioanalytical, Melbourne, Australia
Method basis
15 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 5

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

ms_confirm
Purity at 99.93 % with identity confirmed on the same submission is the combination worth having. Either alone leaves a question the other answers.
lot_traceability
Lot HYB-2505-M6859 decodes to a manufacture date consistent with the custody chain above. Traceability plus 99.93 % is a complete story; either alone is half of one.
ppm_error
The distribution of ppm error by instrument class in this index is wide enough that a single figure like +15.1 ppm carries little on its own. What carries is whether the same instrument produced similar excursions on adjacent runs, and the laboratory page has that.
bootstrap_ci
One measurement, one instrument, one day. There is no interval around +15.1 ppm on this record and treating it as a point estimate overstates what a single determination supports.
Section 7

Related records

Same batch — lot HYB-2505-M6859 n=5

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019379HYB-2505-M6859Janoshik2025-Q299.834.7798.5Buyer-sourced0FAIL
AX-2025-019380HYB-2505-M6859Janoshik2025-Q299.935.07Buyer-sourced0FAIL
AX-2025-019382HYB-2505-M6859Janoshik2025-Q299.874.94101.4Buyer-sourced0FAIL
AX-2025-019383HYB-2505-M6859Kestrel2025-Q299.825.1999.8Buyer-sourced0FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent HYB records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042083MOTS-cHYB-2606-D7858Medutest2026-Q399.932.02Buyer-sourced0PASS
AX-2026-042090MOTS-cHYB-2606-D7858Janoshik2026-Q399.572.36Buyer-sourced1FAIL
AX-2026-042084MOTS-cHYB-2606-D7858Janoshik2026-Q399.282.79107.3Buyer-sourced0PASS
AX-2026-042087MOTS-cHYB-2606-D7858Janoshik2026-Q399.543.05Buyer-sourced0PASS
AX-2026-042085MOTS-cHYB-2606-D7858Janoshik2026-Q399.512.31Buyer-sourced0PASS
AX-2026-042088MOTS-cHYB-2606-D7858PeptideMeter2026-Q399.222.21Buyer-sourced0PASS
AX-2026-042086MOTS-cHYB-2606-D7858Janoshik2026-Q399.933.02Buyer-sourced1MARGINAL
AX-2026-042091CJC-1295 with DACHYB-2608-E7391Janoshik2026-Q399.385.53Buyer-sourced0PASS