AssayIndex

AX-2025-019796

MK-677 (Ibutamoren mesylate) · 250 mg declared · Hunan Aslsen Technology Co., Ltd. · lot HOMO-2506-L4686

FAILIDENTITY CONSISTENT
Report ID
AX-2025-019796
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
Homopeptide — Hunan Aslsen Technology Co., Ltd.
Batch / lot
HOMO-2506-L4686
Declared label claim
250mg
Laboratory
Janoshik Analytical
Assay date
29 Nov 2025
Submitted
01 Dec 2025
Quarter
2025-Q4
Submitter
hilic_amide
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.93% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 1.5PASS
Largest single impurityRP-HPLC — free base (des-mesylate, −96 Da)0.04% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)624.2181DaNOT TESTED
Mass accuracyobserved vs theoretical0.0ppm± 10PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate1.00%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography15.05%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.77%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.192.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient14.62min13.86 ± 0.30 (normalised)FAIL
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.990.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²92,918≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.20no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02425484972749698 MK-677 (Ibutamoren mesylate)14.62 min · 99.93 % 14.66 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 92,918, and skew follows the reported asymmetry factor of 0.99. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.04 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak14.624,856,90899.93
2free base (des-mesylate, −96 Da)14.661,9440.04-96.011
3spiroindane regioisomer15.061,4580.030.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.23[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2181 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.1163-0.000053.2
1+625.2254625.22540.0000100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence -0.03 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)0.040.04
Water (%)0.81.00
Counter-ion (%)not stated15.05
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (2–8 °C, 20 d) → laboratory (courier, ambient, 5 d) → assay.
Assay date
29 Nov 2025
Submitted to the index
01 Dec 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sig_figs
Two decimal places on 99.93 % implies repeatability better than 0.01 pp, which no laboratory here claims. The number is sound; the printed precision is more than the method carries.
Index data team

Two decimal places are retained because the source reports carry them and truncating would discard information where a laboratory genuinely reports it. The uncertainty budget on /methods/uncertainty-budget/ is the right thing to read alongside any purity figure on this site.

esi_tof
The observed monoisotopic mass on this record reconciles with the theoretical value to four decimal places, which is the arithmetic the index re-derives in its own build check rather than accepting from the report.
ion_pair_ip
The resolution figure sits in the system-suitability block with no PASS or FAIL beside it. That is deliberate: the index reports it and adjudicates nothing against it.
epitalon_bAsp
A beta-aspartyl isomer sits a tenth of a minute away and is mass-identical. That is the archetype of a pair where resolution is a compound property and no rule should adjudicate it.
Section 7

Related records

Same batch — lot HOMO-2506-L4686 n=13

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019787HOMO-2506-L4686Janoshik2025-Q499.931.8191.7Buyer-sourced0FAIL
AX-2025-019788HOMO-2506-L4686Janoshik2025-Q499.721.45Buyer-sourced0FAIL
AX-2025-019789HOMO-2506-L4686Medutest2025-Q499.931.59Buyer-sourced0FAIL
AX-2025-019790HOMO-2506-L4686Medutest2025-Q499.931.09Buyer-sourced1FAIL
AX-2025-019791HOMO-2506-L4686VendorInvestigate2025-Q499.701.37102.4Buyer-sourced0FAIL
AX-2025-019792HOMO-2506-L4686Janoshik2025-Q499.891.4095.5Buyer-sourced0FAIL
AX-2025-019793HOMO-2506-L4686Janoshik2025-Q499.511.23Buyer-sourced0FAIL
AX-2025-019794HOMO-2506-L4686PeptideMeter2025-Q499.931.59Buyer-sourced0FAIL
AX-2025-019795HOMO-2506-L4686PeptideMeter2025-Q499.931.31103.3Buyer-sourced0FAIL
AX-2025-019797HOMO-2506-L4686Janoshik2025-Q499.801.22105.9Buyer-sourced0FAIL
AX-2025-019798HOMO-2506-L4686Medutest2025-Q499.931.34Buyer-sourced1FAIL
AX-2025-019799HOMO-2506-L4686Kestrel2025-Q499.931.74Buyer-sourced1FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent Homopeptide records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042437RetatrutideHOMO-2605-V4718Nordanalyt2026-Q398.683.67102.8Buyer-sourced0PASS
AX-2026-042424SemaglutideHOMO-2604-X3806PeptideMeter2026-Q398.854.8792.0Buyer-sourced0PASS
AX-2026-042503IGF-1 LR3HOMO-2607-P5131Janoshik2026-Q399.365.99Buyer-sourced0PASS
AX-2026-042492SS-31 (Elamipretide)HOMO-2604-D5484Medutest2026-Q399.932.40Buyer-sourced0PASS
AX-2026-042491SS-31 (Elamipretide)HOMO-2604-D5484Kestrel2026-Q399.933.24Supplier-supplied0PASS
AX-2026-042473LL-37HOMO-2602-G5165Janoshik2026-Q399.015.00Buyer-sourced0PASS
AX-2026-042441RetatrutideHOMO-2605-V4718Medutest2026-Q398.934.22Buyer-sourced0PASS
AX-2026-042474LL-37HOMO-2602-G5165Janoshik2026-Q399.185.44Buyer-sourced0PASS