AssayIndex

AX-2025-019880

MK-677 (Ibutamoren mesylate) · 500 mg declared · Hubei Jianxiang Bioscience Co., Ltd. · lot HJ-2501-G5680

FAILVERIFIED
Report ID
AX-2025-019880
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
HJ — Hubei Jianxiang Bioscience Co., Ltd.
Batch / lot
HJ-2501-G5680
Declared label claim
500mg
Laboratory
Janoshik Analytical
Assay date
04 May 2025
Submitted
10 May 2025
Quarter
2025-Q2
Submitter
l.broberg
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.46% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.54% area≤ 1.5PASS
Largest single impurityRP-HPLC — free base (des-mesylate, −96 Da)0.22% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)624.2169DaNOT TESTED
Mass accuracyobserved vs theoretical-2.0ppm± 10PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate5.41%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography13.46%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.23%NOT TESTED
Endotoxinkinetic chromogenic LAL0.22EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite cake, partially collapsedwhite to off-white intact cakeFAIL
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.652.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient14.05min13.86 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.060.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²40,333≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.14no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01601320148026403 MK-677 (Ibutamoren mesylate)14.05 min · 99.46 % 14.09 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 40,333, and skew follows the reported asymmetry factor of 1.06. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.22 % impurity against a 99.46 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak14.054,834,06499.46
2free base (des-mesylate, −96 Da)14.0910,6930.22-96.011
3O-desmethyl metabolite analogue (−14 Da)13.538,2630.17-14.016
4spiroindane regioisomer14.493,8880.080.000
5sulfonamide hydrolysis product (+18 Da)13.193,4020.07+18.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.22[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2169 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.1157-0.000656.3
1+625.2254625.2242-0.0012100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.7799.46divergence +0.04 pp vs batch median
Total impurities (% area)not stated0.54
Largest single impurity (% area)not stated0.22
Water (%)not stated5.41
Counter-ion (%)3.413.46
Peptide content (%w/w)92.5not determined
Endotoxin (EU/mg)not stated0.22
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → third-party forwarder (22 d) → laboratory (courier, cold pack, 12 d) → assay.
Assay date
04 May 2025
Submitted to the index
10 May 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sig_figs
Two decimal places on 99.46 % implies repeatability better than 0.01 pp, which no laboratory here claims. The number is sound; the printed precision is more than the method carries.
Index data team

Two decimal places are retained because the source reports carry them and truncating would discard information where a laboratory genuinely reports it. The uncertainty budget on /methods/uncertainty-budget/ is the right thing to read alongside any purity figure on this site.

c18_2p6
Column chemistry flatters or punishes a figure like this. A core-shell column at this gradient resolves the close-eluting family that a fully porous 5 µm bed merges, so 99.46 % here is a harder number than the same figure from a coarser column.
diode_array
Photodiode-array spectral homogeneity across the main peak would convert 99.46 % from a good number into a checked one. It is a free measurement on any instrument that already has the detector.
Section 7

Related records

Same batch — lot HJ-2501-G5680 n=9

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019877HJ-2501-G5680VendorInvestigate2025-Q299.855.5191.1Buyer-sourced0FAIL
AX-2025-019878HJ-2501-G5680Medutest2025-Q299.935.75Buyer-sourced0FAIL
AX-2025-019879HJ-2501-G5680Medutest2025-Q299.935.65Buyer-sourced1FAIL
AX-2025-019881HJ-2501-G5680PeptideMeter2025-Q299.424.81Laboratory-retained0FAIL
AX-2025-019882HJ-2501-G5680Kestrel2025-Q299.935.42Buyer-sourced0FAIL
AX-2025-019883HJ-2501-G5680Medutest2025-Q299.165.3591.3Buyer-sourced0FAIL
AX-2025-019884HJ-2501-G5680Janoshik2025-Q299.675.44103.4Buyer-sourced0FAIL
AX-2025-019885HJ-2501-G5680PeptideMeter2025-Q299.735.3998.8Supplier-supplied0FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent HJ records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042595SemaglutideHJ-2608-C7002Janoshik2026-Q399.503.55Buyer-sourced1MARGINAL
AX-2026-042598SemaglutideHJ-2608-C7002Janoshik2026-Q399.593.84Buyer-sourced0PASS
AX-2026-042605SemaglutideHJ-2608-C7002Janoshik2026-Q399.033.37107.3Buyer-sourced0PASS
AX-2026-042602SemaglutideHJ-2608-C7002Nordanalyt2026-Q399.213.5092.0Buyer-sourced0PASS
AX-2026-042603SemaglutideHJ-2608-C7002Janoshik2026-Q399.163.42105.9Buyer-sourced0PASS
AX-2026-042528GHRP-6HJ-2603-R5329VendorInvestigate2026-Q398.691.8795.8Buyer-sourced0FAIL
AX-2026-042526GHRP-6HJ-2603-R5329Medutest2026-Q399.373.06Laboratory-retained0PASS
AX-2026-042527GHRP-6HJ-2603-R5329VendorInvestigate2026-Q399.212.7793.2Buyer-sourced0PASS