AssayIndex

AX-2025-020620

MK-677 (Ibutamoren mesylate) · 500 mg declared · GL Biochem (Shanghai) Ltd. · lot GLBI-2501-Y7989

FAILIDENTITY CONSISTENT
Report ID
AX-2025-020620
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
GL Biochem — GL Biochem (Shanghai) Ltd.
Batch / lot
GLBI-2501-Y7989
Declared label claim
500mg
Laboratory
PeptideMeter
Assay date
28 May 2025
Submitted
08 Jun 2025
Quarter
2025-Q2
Submitter
i.ndiaye
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm98.82% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks1.18% area≤ 1.5PASS
Largest single impurityRP-HPLC — free base (des-mesylate, −96 Da)0.70% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)624.2192DaNOT TESTED
Mass accuracyobserved vs theoretical+1.8ppm± 10PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.94%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography14.26%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.35%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite cake, partial shrinkage from vial wallwhite to off-white intact cakeFAIL
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.222.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient13.01min13.01 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.020.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²63,161≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.18no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02200440065998799 MK-677 (Ibutamoren mesylate)13.01 min · 98.82 % 13.055.36 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 63,161, and skew follows the reported asymmetry factor of 1.02. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.70 % impurity against a 98.82 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak13.014,802,95898.82
2free base (des-mesylate, −96 Da)13.0534,0220.70-96.011
3sulfonamide hydrolysis product (+18 Da)12.2114,5810.30+18.011
4spiroindane regioisomer13.423,8880.080.000
5O-desmethyl metabolite analogue (−14 Da)12.522,4300.05-14.016
6residual DMF (process solvent)5.362,4300.05-551.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.23[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2192 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.11690.000654.7
1+625.2254625.22650.0011100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.0398.82divergence +0.15 pp vs batch median
Total impurities (% area)0.971.18
Largest single impurity (% area)0.410.70
Water (%)3.94.94
Counter-ion (%)not stated14.26
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)0.45not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 25 d) → laboratory (courier, cold pack, 5 d) → assay.
Assay date
28 May 2025
Submitted to the index
08 Jun 2025
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

lambda_214
Detection wavelength does not affect a mass determination but it does affect the purity figure sitting next to it. Both are stated on this record, which is the point.
ms_confirm
An orthogonal identity method on the same lot would make this the strongest class of record the index holds. Mass plus retention is already better than most.
chain_custody
A retail vial at 98.82 % is worth more evidentially than a selected vial at a higher figure. That is the whole argument for recording provenance at all.
Section 7

Related records

Same batch — lot GLBI-2501-Y7989 n=8

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020618GLBI-2501-Y7989PeptideMeter2025-Q298.735.01Buyer-sourced1FAIL
AX-2025-020619GLBI-2501-Y7989Nordanalyt2025-Q298.935.11Buyer-sourced1FAIL
AX-2025-020621GLBI-2501-Y7989Janoshik2025-Q299.115.07106.9Supplier-supplied1FAIL
AX-2025-020622GLBI-2501-Y7989PeptideMeter2025-Q298.525.49Supplier-supplied1FAIL
AX-2025-020623GLBI-2501-Y7989Janoshik2025-Q298.974.56104.5Supplier-supplied1FAIL
AX-2025-020624GLBI-2501-Y7989Janoshik2025-Q298.694.68Buyer-sourced1FAIL
AX-2025-020625GLBI-2501-Y7989Kestrel2025-Q299.204.8893.2Buyer-sourced1FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent GL Biochem records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043179Kisspeptin-10GLBI-2608-N7715Medutest2026-Q398.974.37Buyer-sourced1MARGINAL
AX-2026-043178Kisspeptin-10GLBI-2608-N7715Janoshik2026-Q398.504.55Buyer-sourced1MARGINAL
AX-2026-043166L-Glutathione (reduced)GLBI-2606-S7352Janoshik2026-Q399.018.84105.4Laboratory-retained1MARGINAL
AX-2026-043184Kisspeptin-10GLBI-2608-N7715Janoshik2026-Q398.993.63100.6Supplier-supplied1MARGINAL
AX-2026-043185Kisspeptin-10GLBI-2608-N7715Medutest2026-Q398.713.71107.0Buyer-sourced1MARGINAL
AX-2026-043165L-Glutathione (reduced)GLBI-2606-S7352Medutest2026-Q399.478.60Supplier-supplied1MARGINAL
AX-2026-043182Kisspeptin-10GLBI-2608-N7715Janoshik2026-Q398.933.8695.7Buyer-sourced1MARGINAL
AX-2026-043183Kisspeptin-10GLBI-2608-N7715PeptideMeter2026-Q398.544.17102.2Buyer-sourced1MARGINAL