AssayIndex

AX-2026-041486

CJC-1295 (no DAC) · 5 mg declared · Qingdao Sigma Chemical Co., Ltd. · lot QSC-2601-B6118

MARGINALIDENTITY CONSISTENT
Report ID
AX-2026-041486
Compound
CJC-1295 (no DAC)
Compound class
Growth-hormone axis peptides
Supplier
QSC — Qingdao Sigma Chemical Co., Ltd.
Batch / lot
QSC-2601-B6118
Declared label claim
5mg
Laboratory
PeptideMeter
Assay date
20 May 2026
Submitted
08 Jun 2026
Quarter
2026-Q2
Submitter
Contributor #B-5903
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm99.10% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.90% area≤ 2.0PASS
Largest single impurityRP-HPLC — truncated (1-24)0.43% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula3365.7402DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)3365.7308DaNOT TESTED
Mass accuracyobserved vs theoretical-2.8ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.96%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography4.83%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.64%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.332.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient12.19min12.07 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.950.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²51,701≥ 20,000PASS
Resolution to nearest impurityvs deamidated (+1 Da)1.02no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02195438965848778 CJC-1295 (no DAC)12.19 min · 99.10 % 11.11 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 51,701, and skew follows the reported asymmetry factor of 0.95. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.43 % impurity against a 99.10 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1CJC-1295 (no DAC) — main peak12.194,816,56799.10
2truncated (1-24)11.1120,8990.43-570.291
3des-Tyr1 (−163 Da)11.6916,0390.33-163.063
4native GRF (1-29) (−59 Da)11.874,3740.09-58.995
5deamidated (+1 Da)11.971,4580.03+0.984
6acetyl adduct (+42 Da)12.609720.02+42.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 3365.7402 Da, computed from C152H252N44O42. All ppm figures on this site are against monoisotopic values — see why that matters.

02550751005507751000122514501675 [M+3H]3+1122.92[M+4H]4+842.44[M+2H]2+1683.87 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 3365.7308 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
5+674.1553674.1534-0.00198.6
4+842.4423842.4400-0.002356.3
3+1122.92071122.9175-0.0032100.0
2+1683.87741683.8727-0.004751.3
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.4699.10divergence +0.39 pp vs batch median
Total impurities (% area)1.190.90
Largest single impurity (% area)not stated0.43
Water (%)4.64.96
Counter-ion (%)6.44.83
Peptide content (%w/w)88.4not determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 12 d) → laboratory (hand-carried, 11 d) → assay.
Assay date
20 May 2026
Submitted to the index
08 Jun 2026
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

dimer_disulfide
Any covalent dimer would appear at roughly twice the parent mass, and on a cysteine-containing sequence at twice the parent minus two hydrogens. The envelope on this record shows no series at either offset.
buyer_sourced
Buyer-sourced through an ordinary retail order, so the supplier had no opportunity to select the vial. This is the provenance class the index weights and it is roughly 87 % of the dataset.
sample_vs_retail
Where a supplier-supplied result on the same lot also exists, the pair is the informative object rather than either record alone. The batch page shows whether one does.
Section 7

Related records

Same batch — lot QSC-2601-B6118 n=6

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041484QSC-2601-B6118Nordanalyt2026-Q299.034.98105.4Buyer-sourced1MARGINAL
AX-2026-041485QSC-2601-B6118PeptideMeter2026-Q299.155.02102.7Buyer-sourced1MARGINAL
AX-2026-041487QSC-2601-B6118VendorInvestigate2026-Q298.945.3192.1Buyer-sourced1MARGINAL
AX-2026-041488QSC-2601-B6118PeptideMeter2026-Q299.505.46101.4Buyer-sourced1MARGINAL
AX-2026-041489QSC-2601-B6118Janoshik2026-Q298.925.2096.3Buyer-sourced1MARGINAL
Other recent CJC-1295 (no DAC) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042942MKMMKM-2603-V3346Janoshik2026-Q399.523.43Supplier-supplied0PASS
AX-2026-041599QSCQSC-2606-V7416VendorInvestigate2026-Q397.963.52Buyer-sourced1FAIL
AX-2026-042784GGPepsGGPE-2606-E1234Medutest2026-Q398.274.55Buyer-sourced0PASS
AX-2026-042939MKMMKM-2603-V3346PeptideMeter2026-Q399.443.39Buyer-sourced0PASS
AX-2026-041601QSCQSC-2606-V7416Kestrel2026-Q398.334.10Buyer-sourced1MARGINAL
AX-2026-042945MKMMKM-2603-V3346PeptideMeter2026-Q399.393.54Laboratory-retained0PASS
AX-2026-042786GGPepsGGPE-2606-E1234Janoshik2026-Q398.223.77Buyer-sourced0PASS
AX-2026-041602QSCQSC-2606-V7416VendorInvestigate2026-Q398.363.38101.8Buyer-sourced1MARGINAL
Other recent QSC records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041599CJC-1295 (no DAC)QSC-2606-V7416VendorInvestigate2026-Q397.963.52Buyer-sourced1FAIL
AX-2026-041601CJC-1295 (no DAC)QSC-2606-V7416Kestrel2026-Q398.334.10Buyer-sourced1MARGINAL
AX-2026-041602CJC-1295 (no DAC)QSC-2606-V7416VendorInvestigate2026-Q398.363.38101.8Buyer-sourced1MARGINAL
AX-2026-041477TriptorelinQSC-2607-C5749Nordanalyt2026-Q399.533.42Buyer-sourced0PASS
AX-2026-041600CJC-1295 (no DAC)QSC-2606-V7416Nordanalyt2026-Q397.744.91100.9Buyer-sourced1FAIL
AX-2026-041603CJC-1295 (no DAC)QSC-2606-V7416PeptideMeter2026-Q398.434.20Buyer-sourced1MARGINAL
AX-2026-041606CJC-1295 (no DAC)QSC-2606-V7416Janoshik2026-Q398.033.58Buyer-sourced1MARGINAL
AX-2026-041585LiraglutideQSC-2605-W7381Medutest2026-Q399.595.0992.8Laboratory-retained0PASS