AssayIndex

AX-2026-042580

GHRP-2 · 5 mg declared · Hubei Jianxiang Bioscience Co., Ltd. · lot HJ-2512-X6599

MARGINALIDENTITY CONSISTENT
Report ID
AX-2026-042580
Compound
GHRP-2
Compound class
Growth-hormone axis peptides
Supplier
HJ — Hubei Jianxiang Bioscience Co., Ltd.
Batch / lot
HJ-2512-X6599
Declared label claim
5mg
Laboratory
Janoshik Analytical
Assay date
11 Mar 2026
Submitted
16 Mar 2026
Quarter
2026-Q1
Submitter
Contributor #M-7735
Sample provenance
Laboratory-retained
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.93% area≥ 99.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 1.0PASS
Largest single impurityRP-HPLC — [D-2-Nal]-epimer0.04% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula817.4275DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)817.4277DaNOT TESTED
Mass accuracyobserved vs theoretical+0.3ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate3.73%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography5.38%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.51%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.172.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient8.90min9.06 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.080.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²64,647≥ 20,000PASS
Resolution to nearest impurityvs [D-2-Nal]-epimer0.98no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

031786355953312710 GHRP-28.90 min · 99.93 % 8.76 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 64,647, and skew follows the reported asymmetry factor of 1.08. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.04 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1GHRP-2 — main peak8.904,856,90899.93
2[D-2-Nal]-epimer8.761,9440.040.000
3des-Lys (−128 Da)8.661,4580.03-128.095
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 817.4275 Da, computed from C45H55N9O6. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100350450550650750850 [M+1H]1+818.43[M+2H]2+409.72 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 817.4277 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+409.7210409.72110.000150.3
1+818.4348818.43500.0002100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)100.099.93divergence +0.07 pp vs batch median
Total impurities (% area)0.000.07
Largest single impurity (% area)not stated0.04
Water (%)1.33.73
Counter-ion (%)3.75.38
Peptide content (%w/w)94.4not determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Laboratory-retained
Evidentiary weight
Provenance documented, selection uncontrolled.
Chain of custody
Laboratory retained sample (−20 °C, 1 d since original receipt) → re-assay.
Assay date
11 Mar 2026
Submitted to the index
16 Mar 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

baseline_noise
Baseline on this trace is flat enough that the reporting threshold is doing real work rather than hiding peaks in noise. That is a precondition for believing 99.93 % and it is not always met.
aib_coupling
Hindered couplings are where a synthesis loses purity, and the deletion products they leave are the first thing to look for. On this record they are not there in quantity.
ms_confirm
+0.3 ppm at this mass is a clean identity confirmation. With retention at 8.90 min, GHRP-2 is established as the species measured. Note what it does not exclude: a mass-identical diastereomer, which no mass measurement of any resolution can.
Where two compounds elute within a third of a minute, a mass at this accuracy is what separates them. Retention alone would not have.
Section 7

Related records

Same batch — lot HJ-2512-X6599 n=1

This is the only report on this lot. One report is not a batch characterisation.

Other recent GHRP-2 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043535SIGSIG-2603-6031Janoshik2026-Q399.121.26105.7Buyer-sourced0PASS
AX-2026-043541SIGSIG-2603-6031PeptideMeter2026-Q399.062.08107.4Buyer-sourced1MARGINAL
AX-2026-043539SIGSIG-2603-6031Janoshik2026-Q398.951.74100.4Buyer-sourced1FAIL
AX-2026-043534SIGSIG-2603-6031Medutest2026-Q399.112.1589.8Buyer-sourced1MARGINAL
AX-2026-043542SIGSIG-2603-6031VendorInvestigate2026-Q399.051.43Buyer-sourced1FAIL
AX-2026-043543SIGSIG-2603-6031Janoshik2026-Q399.381.7098.6Buyer-sourced0PASS
AX-2026-043544SIGSIG-2603-6031PeptideMeter2026-Q399.571.51105.4Buyer-sourced0PASS
AX-2026-043538SIGSIG-2603-6031Kestrel2026-Q398.931.72Buyer-sourced0FAIL
Other recent HJ records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042595SemaglutideHJ-2608-C7002Janoshik2026-Q399.503.55Buyer-sourced1MARGINAL
AX-2026-042598SemaglutideHJ-2608-C7002Janoshik2026-Q399.593.84Buyer-sourced0PASS
AX-2026-042605SemaglutideHJ-2608-C7002Janoshik2026-Q399.033.37107.3Buyer-sourced0PASS
AX-2026-042602SemaglutideHJ-2608-C7002Nordanalyt2026-Q399.213.5092.0Buyer-sourced0PASS
AX-2026-042603SemaglutideHJ-2608-C7002Janoshik2026-Q399.163.42105.9Buyer-sourced0PASS
AX-2026-042528GHRP-6HJ-2603-R5329VendorInvestigate2026-Q398.691.8795.8Buyer-sourced0FAIL
AX-2026-042526GHRP-6HJ-2603-R5329Medutest2026-Q399.373.06Laboratory-retained0PASS
AX-2026-042527GHRP-6HJ-2603-R5329VendorInvestigate2026-Q399.212.7793.2Buyer-sourced0PASS