AssayIndex

AX-2026-043485

MK-677 (Ibutamoren mesylate) · 1000 mg declared · Bachem Holding (Suzhou) Co., Ltd. · lot BCH-2510-P5124

FAILVERIFIED
Report ID
AX-2026-043485
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
BCH — Bachem Holding (Suzhou) Co., Ltd.
Batch / lot
BCH-2510-P5124
Declared label claim
1000mg
Laboratory
PeptideMeter
Assay date
20 Dec 2025
Submitted
13 Jan 2026
Quarter
2025-Q4
Submitter
f.stanescu
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm97.95% area≥ 98.5FAIL
Total impuritiesRP-HPLC, sum of reported peaks2.05% area≤ 1.5FAIL
Largest single impurityRP-HPLC — O-desmethyl metabolite analogue (−14 Da)0.91% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)624.2201DaNOT TESTED
Mass accuracyobserved vs theoretical+3.2ppm± 10PASS
Total peptide contentby difference from the gravimetric mass balance78.93%w/wNOT TESTED
Target-compound contenttotal peptide content × purity77.31%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen1150.59mg1000 mg declaredNOT TESTED
Recovered target peptidegross fill × target content889.521mg1000 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim89.0%90.0 – 110.0FAIL
Water contentKarl Fischer, coulometric, duplicate5.99%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography14.62%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.46%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite to pale-yellow cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.492.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient13.05min13.01 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.130.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²63,159≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.18no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02054410861628216 MK-677 (Ibutamoren mesylate)13.05 min · 97.95 % 12.565.40 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 63,159, and skew follows the reported asymmetry factor of 1.13. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.91 % impurity against a 97.95 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak13.054,760,67497.95
2O-desmethyl metabolite analogue (−14 Da)12.5644,2290.91-14.016
3sulfonamide hydrolysis product (+18 Da)12.2536,9380.76+18.011
4free base (des-mesylate, −96 Da)13.0911,1790.23-96.011
5spiroindane regioisomer13.464,3740.090.000
6residual DMF (process solvent)5.402,9160.06-551.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.23[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2201 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.11730.001057.1
1+625.2254625.22740.0020100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer5.99
Counter-ion (mesylate)ion chromatography14.62
Residual solvent + inorganic residueestimated0.46
Total peptide contentby difference78.93
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)97.9497.95divergence -0.01 pp vs batch median
Total impurities (% area)2.062.05
Largest single impurity (% area)not stated0.91
Water (%)4.55.99
Counter-ion (%)not stated14.62
Peptide content (%w/w)not stated78.93
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 16 d) → laboratory (hand-carried, 6 d) → assay.
Assay date
20 Dec 2025
Submitted to the index
13 Jan 2026
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 5

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sample_vs_retail
Where a supplier-supplied result on the same lot also exists, the pair is the informative object rather than either record alone. The batch page shows whether one does.
price_per_mg
The index cannot verify that the vial assayed is representative of the lot it came from, and says so on every record. Provenance narrows that gap; it does not close it.
plate_count
Nothing on this record is flagged for resolution and nothing will be. The figure exists so the reader can weight the purity number, which is its only purpose.
acetate_only
Salt form affects hygroscopicity as well as mass. Acetate cakes generally pick up less water than trifluoroacetate ones, which shows up in the water column rather than this one.
low_n
Noted. Logged against the batch rollup.
Section 7

Related records

Same batch — lot BCH-2510-P5124 n=1

This is the only report on this lot. One report is not a batch characterisation.

Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent BCH records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043445BPC-157BCH-2603-G4350Nordanalyt2026-Q398.424.8793.6Buyer-sourced1MARGINAL
AX-2026-043440BPC-157BCH-2603-G4350VendorInvestigate2026-Q398.614.11Buyer-sourced1MARGINAL
AX-2026-043442BPC-157BCH-2603-G4350Janoshik2026-Q398.654.78Buyer-sourced1MARGINAL
AX-2026-043471CJC-1295 with DACBCH-2607-H5235Janoshik2026-Q397.465.48Buyer-sourced1FAIL
AX-2026-043477CJC-1295 with DACBCH-2607-H5235VendorInvestigate2026-Q397.625.3299.6Buyer-sourced1MARGINAL
AX-2026-043449BPC-157BCH-2603-G4350Kestrel2026-Q399.744.9291.3Supplier-supplied2MARGINAL
AX-2026-043448BPC-157BCH-2603-G4350Janoshik2026-Q398.554.69106.9Buyer-sourced1MARGINAL
AX-2026-043470CJC-1295 with DACBCH-2607-H5235Janoshik2026-Q397.766.1199.3Supplier-supplied1MARGINAL